Idiopathic Ventricular Arrhythmia Ablation Using Non-Fluoroscopic Catheter Visualization System.

Ueda Akiko, Soejima Kyoko, Miwa Yosuke, Takeuchi Shinsuke, Nagaoka Mika, Momose Yuichi, Matsushita Noriko, Hoshida Kyoko, Miyakoshi Mutsumi, Togashi Ikuko, Maeda Akiko, Hagiwara Yo, Sato Toshiaki, Yoshino Hideaki

СтатьяПеревод пока не подготовлен

Аннотация

A novel, sensor-based, electromagnetic, non-fluoroscopic catheter visualization (NFCV) system shows tracked catheters directly on pre-acquired fluoroscopy or cine loops. We aimed to evaluate the effectiveness of this system in the setting of catheter ablation for idiopathic premature ventricular contractions/ventricular tachycardia (i-PVC/VT).A total of 30 i-PVC/VT ablation procedures were performed using the NFCV system in conjunction with three-dimensional electroanatomic mapping system (3D-EMS) between January 2013 and April 2017. At the beginning of the procedure, cine loops of right and left anterior oblique views were obtained and replayed for subsequent mapping and ablation. Right ventriculography, aortography, or coronary angiography was performed, depending on the chamber of interest. We reviewed procedural parameters, comparing with the i-PVC/VT ablation procedure using conventional fluoroscopy (CvF) system (pre-, and post-NFCV implementation; 20 and 11 cases, respectively).I-PVC/VTs were successfully eliminated in 26 patients (87%) in the NFCV group and in 26 (84%) in the CvF group (P = 1.000). The procedure time in the NFCV group was comparable to that in the CvF group (119.8 versus 125.0 minutes, respectively, P = 0.868); the total fluoroscopy time was significantly shorter in the NFCV group (3.3 versus 16.6 minutes, P < 0.001). One patient in the CvF group experienced cardiac tamponade, requiring pericardial drainage. No major complications were encountered in the NFCV group.NFCV system, in conjunction with 3D-EMS, was safe and feasible for i-PVC/VT mapping and ablation. The system contributed to dramatically reduced fluoroscopy time, compared with CvF.

Для цитирования: Ueda Akiko, Soejima Kyoko, Miwa Yosuke, Takeuchi Shinsuke, Nagaoka Mika, Momose Yuichi, Matsushita Noriko, Hoshida Kyoko, Miyakoshi Mutsumi, Togashi Ikuko, Maeda Akiko, Hagiwara Yo, Sato Toshiaki, Yoshino Hideaki. Idiopathic Ventricular Arrhythmia Ablation Using Non-Fluoroscopic Catheter Visualization System.. International heart journal. 2018. DOI: 10.1536/ihj.18-122.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.