INTRODUCTION

Radiofrequency (RF) catheter ablation (RFCA) of ventricular tachycardia (VT) is an effective method of treatment. However, when arrhythmia has ischemic etiology and originates from the posterosuperior process (PSP) of the left ventricular (LV) base, ablation performed with conventional unipolar energy sources may be challenging or impossible.

METHOD AND RESULT: A 67-year-old male after six unsuccessful RFCA for highly symptomatic VT originating from PSP of LV base underwent successful RFCA using multiple bipolar RF applications delivered between two electrodes located at LV endocardium and adjacent right atrial sites.

CONCLUSION

This case report shows that bipolar RFCA can be used for safe and successful treatment of VT originating from deep PSP of LV base.

Для цитирования: Futyma Piotr, Głuszczyk Ryszard, Futyma Marian, Kułakowski Piotr. Right atrial position of a return electrode for bipolar ablation of the left posterosuperior process ventricular tachycardia.. Pacing and clinical electrophysiology : PACE. 2018. DOI: 10.1111/pace.13554.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.