MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-018-0477-1

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2018

Percutaneous ventricular assist device in ventricular tachycardia ablation: a systematic review and meta-analysis.

Turagam Mohit K, Vuddanda Venkat, Koerber Scott, Garg Jalaj, Yarlagadda Bharath, Dar Tawseef, Aryana Arash, Di Biase Luigi, Natale Andrea, Lakkireddy Dhanunjaya

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

There is a lack of compelling data regarding the benefit of percutaneous ventricular assist devices (PVAD) in patients undergoing ventricular tachycardia (VT) ablation. The study aims to conduct a meta-analysis comparing the safety and efficacy of PVAD versus no-PVAD (N-PVAD) during VT ablation.

METHODS

Studies meeting criteria were systematically reviewed. Baseline characteristics and clinical outcomes were extracted and analyzed. A meta-analysis was performed using random-effects model to calculate risk ratio (RR) and mean difference (MD) with 95% confidence interval (CI).

RESULTS

The meta-analysis included five retrospective, observational studies consisting of 2026 patients (PVAD group-284 patients versus N-PVAD group-1742 patients). The PVAD group was sicker with significantly higher VT storm, lower LVEF and greater proportion of NYHA class ≥ III than N-PVAD (p < 0.050). The acute procedural success [RR 0.95, 95% CI, (0.89-1.00), p = 0.070], VT recurrence [RR 0.94, 95% CI, (0.66-1.34), p = 0.740] and mortality [RR 1.28, 95% CI, (0.43-3.83), p = 0.660] were similar on follow-up between PVAD versus N-PVAD. PVAD group also had significantly higher complications [RR 1.83, 95% CI (1.21-2.76), p = 0.004] and longer fluoroscopy [MD + 7.31 min, 95% CI (0.91-13.71), p = 0.030] and procedure time [MD + 71.41 min, 95% CI (31.67-111.14), p < 0.001] than N-PVAD.

CONCLUSION

Patients receiving PVAD support during VT ablation were sicker with no significant difference in acute procedural success, VT recurrence, and mortality compared with N-PVAD. PVAD support was also associated with higher complications and longer fluoroscopy and procedure time. A prospective randomized controlled trial will identify if using PVAD support in unstable patients undergoing VT ablation will impact clinical outcomes.

Для цитирования: Turagam Mohit K, Vuddanda Venkat, Koerber Scott, Garg Jalaj, Yarlagadda Bharath, Dar Tawseef, Aryana Arash, Di Biase Luigi, Natale Andrea, Lakkireddy Dhanunjaya. Percutaneous ventricular assist device in ventricular tachycardia ablation: a systematic review and meta-analysis.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2018. DOI: 10.1007/s10840-018-0477-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.