Evaluating the accuracy of preoperative endoscopic localization for colorectal cancer: post hoc analysis of a prospective study.

Okumura Taishi, Imai Kenichiro, Hotta Kinichi, Ito Sayo, Kishida Yoshihiro, Takada Kazunori, Shigeta Kohei, Kawata Noboru, Yoshida Masao, Yamamoto Yoichi, Ishiwatari Hirotoshi, Sato Junya, Matsubayashi Hiroyuki, Ishiguro Tetsushi, Manabe Shoichi, Yamaoka Yusuke, Kagawa Hiroyasu, Shiomi Akio, Ono Hiroyuki

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Preoperative localization of colorectal cancer (CRC) is essential for accurate resection and treatment planning. However, colonoscopy-based tumor localization may lack optimal accuracy, potentially affecting surgical outcomes and patient management. This study aimed to evaluate the accuracy of colonoscopic localization of CRC and identify predictors of preoperative endoscopic localization errors.

METHODS

This post hoc analysis utilized data from a prospective observational study conducted between June 2016 and June 2018. The accuracy of preoperative colonoscopic localization was compared with surgical localization, which is considered the gold standard. Endoscopic and surgical tumor locations were categorized into eight segments. Surgical localization was confirmed by the presence of visible tattoos during surgery and pathological examination of the resected specimens. Predictors of preoperative endoscopic localization errors were also analyzed.

RESULTS

A total of 342 patients were included in this study. The accuracy of preoperative endoscopic localization compared with surgical localization was 79.2% overall (colon: 90.3%; rectum: 57.8%). Lesion location in the rectum was significantly associated with localization errors (P < 0.001). Tumors limited to the colon, patient age ≥ 65 years [odds ratio (OR) 12.0; 95% confidence interval (CI) 1.57-91.6; P = 0.0167], and an insertion time ≥ 10 min (OR 3.13; 95% CI 1.23-7.92; P = 0.0163) were independently associated with localization errors.

CONCLUSION

Endoscopic CRC localization was accurate in approximately 80% of cases when compared with surgical localization. Patients aged ≥ 65 years and those with insertion times ≥ 10 min in the colon may be at increased risk of localization errors.

CLINICAL TRIAL REGISTRATION: This study protocol was registered in the University Hospital Medical Network Clinical Trials Registry (UMIN000021012).

Для цитирования: Okumura Taishi, Imai Kenichiro, Hotta Kinichi, Ito Sayo, Kishida Yoshihiro, Takada Kazunori, Shigeta Kohei, Kawata Noboru, Yoshida Masao, Yamamoto Yoichi, Ishiwatari Hirotoshi, Sato Junya, Matsubayashi Hiroyuki, Ishiguro Tetsushi, Manabe Shoichi, Yamaoka Yusuke, Kagawa Hiroyasu, Shiomi Akio, Ono Hiroyuki. Evaluating the accuracy of preoperative endoscopic localization for colorectal cancer: post hoc analysis of a prospective study.. Surgical endoscopy. 2025. DOI: 10.1007/s00464-025-11871-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.