One-year clinical outcomes of BioMatrix™-Biolimus A9™ eluting stent: the e-BioMatrix multicenter post marketing surveillance registry in India.

Mehta Ashwin B, Chandra Praveen, Dalal Jamshed, Shetty Prabhakar, Desai Devang, Chocklingam K, Prajapati Jayesh, Kumar Pramod, Magarkar Vilas, Vasawada Apurva, Goyal B K, Kumar Viveka, Rao V Suryaprakash, Babu Ramesh, Parikh Pritesh, Kaul Upendra, Patil Aruna, Mhetre Tushar, Rangnekar Hrishikesh

Оценочное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

The e-BioMatrix is a post marketing multicenter registry with an objective to evaluate the 2 year clinical safety and efficacy outcomes in patients treated with BioMatrix™ - Biolimus A9™ (BA9™) drug eluting stents (DES).

BACKGROUND

Drug-eluting stents still have late-stage disadvantages that might be attributable to the permanent polymer. BioMatrix a new generation DES containing anti-proliferative drug Biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia.

METHODS

This interim analysis consists of a total of 1189 patients with 1418 lesions treated with BioMatrix stent who entered this multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, and 12 months with an extended follow-up of 2 years. Recommended antiplatelet regimen included clopidogrel and aspirin for 12 months.

RESULTS

The mean age was 57.6 ± 10.9 years, 81.8% were males, comorbidity index was 1.20 ± 1.33, 68% presented with acute coronary syndrome, 49% had hypertension and 40.8% had diabetes mellitus. One-year clinical follow-up was completed in 987 patients at the time of interim analysis. The incidence of MACE is 0.45 for 1544 person-year follow-up. There were only 03 cases of ST (01 late ST) reported during this time.

CONCLUSION

This registry demonstrates excellent one-year clinical safety and efficacy of BioMatrix stents. The 1-year result shows that BioMatrix stent may be a suitable alternative as compared to contemporary DESs which are currently available in the market for simple as well complex disease.

Для цитирования: Mehta Ashwin B, Chandra Praveen, Dalal Jamshed, Shetty Prabhakar, Desai Devang, Chocklingam K, Prajapati Jayesh, Kumar Pramod, Magarkar Vilas, Vasawada Apurva, Goyal B K, Kumar Viveka, Rao V Suryaprakash, Babu Ramesh, Parikh Pritesh, Kaul Upendra, Patil Aruna, Mhetre Tushar, Rangnekar Hrishikesh. One-year clinical outcomes of BioMatrix™-Biolimus A9™ eluting stent: the e-BioMatrix multicenter post marketing surveillance registry in India.. Indian heart journal. 2013. DOI: 10.1016/j.ihj.2013.08.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.