MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/joic.12062

Медицинская библиотека · Journal of interventional cardiology · 2013

Detection of Stent Underdeployment by StentBoost Imaging.

Blicq Elodie, Georges Jean-Louis, Elbeainy Elias, Gibault-Genty Géraldine, Benjemaa Khaled, Jerbi Bassem, Livarek Bernard

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the additional value of StentBoost® (SB), a motion-corrected X-ray technique that enhances stent visualization, for the assessment of stent deployment and procedure optimization during routine percutaneous coronary interventions (PCI).

BACKGROUND

Underdeployment and malapposition of stents during PCI may lead to in-stent thrombosis and restenosis. Coronary angiography (CA) is of limited value for the assessment of stent deployment. Intravascular ultrasound and optical imaging techniques are the gold standard, but are used in <10% of routine PCIs.

METHODS

We retrospectively analyzed 260 coronary lesions treated by stent implantation and assessed by SB during 168 consecutive PCI procedures. The immediate results of SB analysis and CA were assessed by 2 independent interventional cardiologists and compared.

RESULTS

A total of 275 stents were implanted; 45% were drug-eluting stents (DES). Direct stenting was performed in 78%. Results of SB and angiography were concordant for 210 lesions: 194 stents were correctly deployed (75%) and 16 were underdeployed (6%), shown by both techniques. In 47 patients (18%), SB detected an underdeployment of the stent whereas the angiographic result was good. Postdilatation was performed on the basis of SB in 89% of these cases. The additional contribution of SB was higher for left main lesions and for DES, and was not affected by coronary calcifications.

CONCLUSIONS

This study confirmed the usefulness of the stent visualization enhancement technique StentBoost® in current PCI practice. SB revealed about 20% underdeployed stents not detected by CA, and allowed for optimizing PCI by ad hoc effective postdilatation.

Для цитирования: Blicq Elodie, Georges Jean-Louis, Elbeainy Elias, Gibault-Genty Géraldine, Benjemaa Khaled, Jerbi Bassem, Livarek Bernard. Detection of Stent Underdeployment by StentBoost Imaging.. Journal of interventional cardiology. 2013. DOI: 10.1111/joic.12062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.