Медицинская библиотека · Annales de biologie clinique · 1995

[Analysis of dot-blot technique for the detection of three autoantibodies (anti-Jo-1, anti-M2, anti-ribosome). Comparison with reference techniques].

Roussel B, Dubel L, Kantara-Doukoure M, Bernard M, Johanet C

Сравнительное исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

A recently commercialized dot-blot (Cyto-Dot, BMD) offered a new method for the detection of three autoantibodies (Ab) anti-Jo-1, anti-M2, and anti-ribosomal protein although their only common point is the cytoplasmic localisation of their respective antigen. These Ab are detected by indirect immunofluorescence (IF) (anti-M2, anti-ribosomal protein), double immunodiffusion (ID) (anti-Jo-1) and western blotting (WB) (anti-M2). The aim of the study was to compare results obtained by the Cyto-Dot with those obtained by our reference technique. One hundred and seventy-seven sera were analysed, divided into four groups: group I (n = 15) with anti-Jo-1 Ab detected by ID, group II (n = 70) with anti-M2 Ab by WB, group III (n = 33) with anti-ribosomal protein Ab by IF (of which, 19 are precipitating by ID), group IV (control group, n = 59) with 31 sera of healthy individuals, six sera of patients with liver diseases resembling primary biliary cirrhosis and 22 with a particular serological profile. Cyto-Dot is very sensitive and specific for the detection of anti-Jo-1 Ab. Also, it represents a reliable method (sensitivity 0.99) for the screening of anti-M2 Ab and for the confirmation of an atypic immunofluorescence pattern. Equivalent to ID for the detection of anti-ribosomal protein Ab, the Cyto-Dot represents a good alternative technique. However, although this new diagnostic method represents a sensitive technique for the detection of the three auto-Ab, unfortunately, it can not be applied for large series.

Для цитирования: Roussel B, Dubel L, Kantara-Doukoure M, Bernard M, Johanet C. [Analysis of dot-blot technique for the detection of three autoantibodies (anti-Jo-1, anti-M2, anti-ribosome). Comparison with reference techniques].. Annales de biologie clinique. 1995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.