Renal dysfunction and atherosclerosis of the neointima following bare metal stent implantation.

Hayano Shinji, Ishii Hideki, Ichimiya Satoshi, Kanashiro Masaaki, Watanabe Junji, Suzuki Susumu, Yoshikawa Daiji, Maeda Kengo, Matsubara Tatsuaki, Murohara Toyoaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Recently, neoatherosclerosis within the neointima after bare metal stent (BMS) implantation, which could cause late restenosis and very late stent thrombosis, has been a cause of concern. Renal dysfunction has been related to late cardiovascular events after coronary intervention. The present study was conducted focusing on the relationship between renal dysfunction and neointimal tissue characteristics with BMS restenosis using integrated backscatter intravascular ultrasound (IB-IVUS).

METHODS

We prospectively performed IB-IVUS in 80 consecutive patients requiring target lesion revascularization after BMS implantation; the patients were divided into two groups according to the estimated glomerular filtration [eGFR: ≥60 (n = 49) and <60 ml/min/1.73 m(2) (n = 31)].

RESULTS

Patients with eGFR <60 ml/min/1.73 m(2) had a significantly higher percentage of lipid tissue volume within the neointima and a lower percentage of fibrous tissue volume than those with eGFR ≥60 ml/min/1.73 m(2) (23.2 ± 9.4 vs. 18.0 ± 7.0%, p = 0.005, and 75.3 ± 9.3 vs. 80.4 ± 7.0%, p = 0.007, respectively). Using logistic regression analysis, eGFR <60 ml/min/1.73 m(2) and duration from stent implantation ≥48 months were independent predictors of increased lipid tissue volume within the neointima (odds ratio, 3.93; 95% confidence interval, 1.15-13.46, p = 0.03, and odds ratio, 7.56; 95% confidence interval, 2.02-28.30, p = 0.003, respectively).

CONCLUSIONS

Lower eGFR levels were associated with greater lipid tissue volume within the neointima after BMS deployment, suggesting the development of atherosclerosis. Renal dysfunction may affect neointimal tissue characteristics and thus leading to an increased risk of late stent failure.

Для цитирования: Hayano Shinji, Ishii Hideki, Ichimiya Satoshi, Kanashiro Masaaki, Watanabe Junji, Suzuki Susumu, Yoshikawa Daiji, Maeda Kengo, Matsubara Tatsuaki, Murohara Toyoaki. Renal dysfunction and atherosclerosis of the neointima following bare metal stent implantation.. American journal of nephrology. 2013. DOI: 10.1159/000353097.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.