BACKGROUND

Laser fenestration in stapedotomy has thermal effect to the vestibule.

AIMS/

OBJECTIVES

To evaluate the role of energy density (fluence) in the severity of postoperative vestibular symptoms.

MATERIALS AND

METHODS

The retrospective chart-review study included 84 patients with otosclerosis that underwent primary laser stapedotomy. Surgical outcomes, including nystagmus, and subjective vestibular symptoms during one-month follow-up, were compared between potassium titanyl phosphate (KTP) and CO2 laser. According to this study and literature, we assessed the relationship between laser parameters and the incidence of persistent vestibular symptoms lasting more than one week after surgery.

RESULTS

The KTP and CO2 laser group included 48 and 36 patients, respectively. Fluence was different between the KTP (637 J/cm2) and CO2 (141 J/cm2) laser (p < .001). The KTP group showed gradual decrease in dizziness during one-month observation period, while the CO2 group exhibited a steep recovery curve in the first postoperative week (9 and 4 d of duration, respectively). The incidence of persistent vestibular symptoms was correlated with both fluence (r = 0.80, p = .01) and spot size (r = -0.74, p = .01).

CONCLUSIONS AND SIGNIFICANCE: Appropriate setting of parameters with lower fluence is desirable for the efficiency and safety of laser stapedotomy.Abbreviations: ABG: air-bone gap; SD: standard deviation.

Для цитирования: Mizoguchi Yoshie, Fujikawa Taro, Kawashima Yoshiyuki, Ito Taku, Kitamura Ken, Noguchi Yoshihiro, Takahashi Masatoki, Honda Keiji, Takeda Takamori, Tsutsumi Takeshi. High fluence in laser stapedotomy aggravates transient subjective dizziness.. Acta oto-laryngologica. 2024. DOI: 10.1080/00016489.2024.2329287.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.