MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jclinane.2023.111324

Медицинская библиотека · Journal of clinical anesthesia · 2023

Recovery and safety with prolonged high-frequency jet ventilation for catheter ablation of atrial fibrillation: A hospital registry study from a New England healthcare network.

Munoz-Acuna Ricardo, Tartler Tim M, Azizi Basit A, Suleiman Aiman, Ahrens Elena, Wachtendorf Luca J, Linhardt Felix C, Chen Guanqing, Tung Patricia, Waks Jonathan W, Schaefer Maximilian S, Sehgal Sankalp

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

STUDY

OBJECTIVE

To investigate post-procedural recovery as well as peri-procedural respiratory and hemodynamic safety parameters with prolonged use of high-frequency jet ventilation (HFJV) versus conventional ventilation in patients undergoing catheter ablation for atrial fibrillation.

DESIGN

Hospital registry study.

SETTING

Tertiary academic teaching hospital in New England.

PATIENTS: 1822 patients aged 18 years and older undergoing catheter ablation between January 2013 and June 2020.

INTERVENTIONS: HFJV versus conventional mechanical ventilation.

MEASUREMENTS: The primary outcome was post-anesthesia care unit (PACU) length of stay. In secondary analyses we assessed the effect of HFJV on intra-procedural hypoxemia, defined as the occurrence of peripheral hemoglobin oxygen saturation (SpO2) <90%, post-procedural respiratory complications (PRC) as well as intra-procedural hypocarbia and hypotension. Multivariable negative binomial and logistic regression analyses, adjusted for patient and procedural characteristics, were applied.

MAIN

RESULTS

1157 patients (63%) received HFJV for a median (interquartile range [IQR]) duration of 307 (253-360) minutes. The median (IQR) length of stay in the PACU was 244 (172-370) minutes in patients who underwent ablation with conventional mechanical ventilation and 226 (163-361) minutes in patients receiving HFJV. In adjusted analyses, patients undergoing HFJV had a longer PACU length of stay (adjusted absolute difference: 37.7 min; 95% confidence interval [CI] 9.7-65.8; p = 0.008). There was a higher risk of intra-procedural hypocarbia (adjusted odds ratio [ORadj] 5.90; 95%CI 2.63-13.23; p < 0.001) and hypotension (ORadj 1.88; 95%CI 1.31-2.72; p = 0.001) in patients undergoing HFJV. No association was found between the use of HFJV and intra-procedural hypoxemia or PRC (p = 0.51, and p = 0.97, respectively).

CONCLUSION

After confounder adjustment, HFJV for catheter ablation procedures for treatment of atrial fibrillation was associated with a longer length of stay in the PACU. It was further associated with an increased risk of intra-procedural abnormalities including abnormal carbon dioxide homeostasis, as well as intra-procedural arterial hypotension.

Для цитирования: Munoz-Acuna Ricardo, Tartler Tim M, Azizi Basit A, Suleiman Aiman, Ahrens Elena, Wachtendorf Luca J, Linhardt Felix C, Chen Guanqing, Tung Patricia, Waks Jonathan W, Schaefer Maximilian S, Sehgal Sankalp. Recovery and safety with prolonged high-frequency jet ventilation for catheter ablation of atrial fibrillation: A hospital registry study from a New England healthcare network.. Journal of clinical anesthesia. 2023. DOI: 10.1016/j.jclinane.2023.111324.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.