MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jcpe.14162

Медицинская библиотека · Journal of clinical periodontology · 2025

Efficacy of Injectable Bone Fillers for Alveolar Ridge Preservation: A Histomorphometrical Analysis.

Schwarz Frank, Ramanauskaite Ausra, Obreja Karina, Lorenz Jonas, Sader Robert, Parvini Puria

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: To assess the efficacy of injectable bone fillers for alveolar ridge preservation (ARP).

MATERIALS AND

METHODS

The mandibular premolars (P2, P3, P4) were bilaterally assigned to ARP in a total of n = 9 beagle dogs. Each P was decapitated and hemisected under preservation of the mesial (i.e., devitalization and filling with calcium hydroxide) and removal of the distal root. The resulting 6 extraction sockets were randomly allocated to a total of four injectable test materials (i.e., bovine bone particles + porcine collagen, lyophilized materials reconstituted with either blood or saline [T1, T2, T4]; or ready-to-use wet material [T3]) and one control material (collagenated bovine bone mineral) (C) as well as one negative control group (N). Primary wound closure was ensured in all test and C groups. At 12 weeks, dissected blocks were prepared for histomorphometrical analyses. Buccal bone height (BBH) was defined as a primary outcome. Lingual bone height (LBH), buccal and lingual bone wall width (BBW and LBW 1, 3 and 5 mm infracrestally), surface area of bone and particles, fibrous tissues, and bone marrows were defined as secondary outcomes. Between-group comparisons were assessed using ANOVA and Mann-Whitney tests.

RESULTS

After 12 weeks, all groups were associated with similar BBH values (BBH: 14.1, 14.0, 13.7, 13.8, 14.3 and 114.2 mm in the T1, T2, T3, T4, C and N groups, respectively; p > 0.05 for all between-group comparisons). The BBW and LBW measurements were comparable among the groups. ARP sites showed a trend towards higher area measurements of bone and particle surfaces compared with the N group (11.5, 11.6, 13.1, 12.5, 9.1 mm2 in T1, T2, T3, T4, C and N groups, respectively). C, T1, T2, T3 and T4 particles were associated with a similar marked grade of osteoconduction and osteointegration within the former extraction socket area.

CONCLUSIONS

Within its limitations, the present study has pointed to the similar efficacy of injectable bone fillers for ARP compared with the particulated bone substitute and negative control.

Для цитирования: Schwarz Frank, Ramanauskaite Ausra, Obreja Karina, Lorenz Jonas, Sader Robert, Parvini Puria. Efficacy of Injectable Bone Fillers for Alveolar Ridge Preservation: A Histomorphometrical Analysis.. Journal of clinical periodontology. 2025. DOI: 10.1111/jcpe.14162.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.