MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3290/j.qi.b6094895

Медицинская библиотека · Quintessence international (Berlin, Germany : 1985) · 2025

Stability of soft tissue augmentation at implant site using volume-stable collagen matrix: 2-year retrospective study.

Mayer Yaniv, Mancini Leonardo, Berg Yarden, Shibli Jamil A, Zeltner Marco, Zigdon Giladi Hadar, Gabay Eran

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the long-term dimensional stability of dental ridges 2 years after soft tissue augmentation using a porcine-derived volume-stable collagen matrix (VCMX) at healing abutment connections.

METHOD AND MATERIALS: A retrospective study was conducted at a private clinic from 2021 to 2023, involving 13 patients who underwent delayed single implant placement in both maxillae and mandible. Three months after implant placement, the buccal soft tissue adjacent to the abutment was augmented with VCMX. Intraoral scans were taken at three points: at implant placement (baseline), 1-month post-grafting, and 24 months after implant loading. Pre-implant CBCT scans were also obtained. Volumetric and profilometric changes were measured at 1, 2, and 3 mm below the mucosal margin by superimposing intraoral and CBCT scans. The Wilcoxon signed-rank test was used for statistical analysis.

RESULTS

All 13 patients completed the 2-year follow-up. Mean volumetric changes at the graft site were + 18.15 ± 15.34 mm3 initially, decreasing by 11.73 ± 21.91 mm3 over 2 years. Profilometric analysis showed increases of 0.72 ± 0.88 mm, 0.54 ± 0.65 mm, and 0.32 ± 0.65 mm at 1, 2, and 3 mm, respectively, 1-month post-grafting. At 24 months, reductions of -0.17 ± 0.77 mm, -0.45 ± 0.58 mm, and -0.48 ± 0.60 mm were recorded.

CONCLUSIONS

VCMX use for soft tissue augmentation shows minimal remodeling after 24 months, supporting its efficacy for soft tissue stability in dental implantology. Further long-term studies are recommended. (Quintessence Int 2025;56:274-283; doi: 10.3290/j.qi.b6094895).

Для цитирования: Mayer Yaniv, Mancini Leonardo, Berg Yarden, Shibli Jamil A, Zeltner Marco, Zigdon Giladi Hadar, Gabay Eran. Stability of soft tissue augmentation at implant site using volume-stable collagen matrix: 2-year retrospective study.. Quintessence international (Berlin, Germany : 1985). 2025. DOI: 10.3290/j.qi.b6094895.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.