DOI 10.1186/s40729-025-00611-z

Медицинская библиотека · International journal of implant dentistry · 2025

Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery.

Al-Haj Husain Adib, Mergen Victor, Valdec Silvio, Al-Haj Husain Nadin, Stadlinger Bernd, Essig Harald, Frauenfelder Thomas, Kessler Peter, Lie Suen An Nynke, Alkadhi Hatem, Winklhofer Sebastian

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare cone-beam computed tomography (CBCT) with photon-counting detector computed tomography (PCD-CT) at equivalent radiation doses, focusing on qualitative and quantitative parameters relevant to dental implant surgery.

METHODS

This ex vivo comparative study of porcine specimens assessed five imaging protocols with both CBCT and PCD-CT at three effective radiation dose levels (high: 360µSv, standard: 145µSv, low: 20µSv) to evaluate image quality, artifact burden, metal artifact susceptibility, and quantitative bone measurements in the mandibular region. Three blinded readers analyzed the data using a 5-point Likert scale (5 = highest to 1 = lowest rating) and performed linear bone measurements at implant planning sites. Statistical analysis included descriptive statistics and inter-reader reliability assessment using intraclass correlation coefficients (ICC).

RESULTS

Each reader evaluated 30 data sets (12 CBCT, 18 PCD-CT), with 24 implant planning sites per imaging protocol. High-dose PCD-CT demonstrated the best image quality and diagnostic interpretability (4.89 ± 0.27), followed by standard-dose PCD-CT and CBCT (4.50 ± 0.73; 4.33 ± 0.61), with low-dose protocols showing intermediate quality with higher artifact burden. In comparison to CBCT, PCD-CT demonstrated superior performance in reducing implant-induced artifacts across all protocols. Quantitative bone measurements showed minimal variability, meeting clinical precision requirements for computer-assisted implant surgery. Both qualitative (ICCs:0.70-0.89; p < 0.001) and quantitative (ICCs:0.79-1; p < 0.001) analyses demonstrated high reliability, regardless of the reader's experience.

CONCLUSIONS

PCD-CT demonstrated superior image quality and reduced artifacts compared with CBCT at all radiation dose levels. These findings highlight PCD-CT's potential to enhance implant planning and improve clinical outcomes with reduced radiation exposure while maintaining diagnostic accuracy.

Для цитирования: Al-Haj Husain Adib, Mergen Victor, Valdec Silvio, Al-Haj Husain Nadin, Stadlinger Bernd, Essig Harald, Frauenfelder Thomas, Kessler Peter, Lie Suen An Nynke, Alkadhi Hatem, Winklhofer Sebastian. Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery.. International journal of implant dentistry. 2025. DOI: 10.1186/s40729-025-00611-z.