MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivab300

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2022

Influence of measurement and sizing techniques in thoracic endovascular aortic repair on outcome in acute complicated type B aortic dissections.

Rychla Miriam, Dueppers Philip, Meuli Lorenz, Rancic Zoran, Menges Anna-Leonie, Kopp Reinhard, Zimmermann Alexander, Reutersberg Benedikt

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Thoracic endovascular aortic repair (TEVAR) is the first-line therapy in acute complicated type B aortic dissections (cTBAD). Nevertheless, no evidence-based consensus on the optimal measurement technique and sizing for TEVAR in cTBAD exists. The aim was to evaluate how different measurement and sizing techniques for TEVAR affect long-term outcomes.

METHODS

Retrospective analysis investigating the association between sizing and postoperative results after TEVAR in patients with cTBAD, treated between January 2003 and December 2020. Diameter measurements were performed perpendicular to a centreline in pre-interventional Computed tomography angiographies. Oversizing was determined by measuring aortic diameter in zone 2 of the aortic arch in relation to the implanted stent graft, and categorized into 2 sizing groups (≤10% and >10%). The primary outcome was freedom from aortic-related events. Secondary outcomes included mortality and a comparison of 3 alternative measurement techniques considering the estimated pre-dissection diameter.

RESULTS

Fifty-seven patients (median age 69, interquartile range 59.6-78.2 years) were included. Stent graft oversizing by ≤10% showed a trend towards fewer aortic-related events hazard ratio 0.455 (95% confidence interval 0.128-1.624, P = 0.225).The 3 measurement techniques using the pre-dissection aortic diameter differed by a mean of 1.7-4.0 mm with a variability of up to 8.4 mm. In none of the 57 patients, the same stent graft would have been chosen based on the different measurement techniques using an oversizing ≤10%.

CONCLUSIONS

TEVAR oversizing of ≤10% in patients with cTBAD might reduce aortic-related events up to 50%. Consensus on measurement techniques of the pre-dissection aortic diameter and stent graft sizing is of paramount importance.

Для цитирования: Rychla Miriam, Dueppers Philip, Meuli Lorenz, Rancic Zoran, Menges Anna-Leonie, Kopp Reinhard, Zimmermann Alexander, Reutersberg Benedikt. Influence of measurement and sizing techniques in thoracic endovascular aortic repair on outcome in acute complicated type B aortic dissections.. Interactive cardiovascular and thoracic surgery. 2022. DOI: 10.1093/icvts/ivab300.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.