MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2013/472564

Медицинская библиотека · Computational and mathematical methods in medicine · 2013

CFD modelling of abdominal aortic aneurysm on hemodynamic loads using a realistic geometry with CT.

Soudah Eduardo, Ng E Y K, Loong T H, Bordone Maurizio, Pua Uei, Narayanan Sriram

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The objective of this study is to find a correlation between the abdominal aortic aneurysm (AAA) geometric parameters, wall stress shear (WSS), abdominal flow patterns, intraluminal thrombus (ILT), and AAA arterial wall rupture using computational fluid dynamics (CFD). Real AAA 3D models were created by three-dimensional (3D) reconstruction of in vivo acquired computed tomography (CT) images from 5 patients. Based on 3D AAA models, high quality volume meshes were created using an optimal tetrahedral aspect ratio for the whole domain. In order to quantify the WSS and the recirculation inside the AAA, a 3D CFD using finite elements analysis was used. The CFD computation was performed assuming that the arterial wall is rigid and the blood is considered a homogeneous Newtonian fluid with a density of 1050 kg/m(3) and a kinematic viscosity of 4 × 10(-3) Pa·s. Parallelization procedures were used in order to increase the performance of the CFD calculations. A relation between AAA geometric parameters (asymmetry index ( β ), saccular index ( γ ), deformation diameter ratio ( χ ), and tortuosity index ( ε )) and hemodynamic loads was observed, and it could be used as a potential predictor of AAA arterial wall rupture and potential ILT formation.

Для цитирования: Soudah Eduardo, Ng E Y K, Loong T H, Bordone Maurizio, Pua Uei, Narayanan Sriram. CFD modelling of abdominal aortic aneurysm on hemodynamic loads using a realistic geometry with CT.. Computational and mathematical methods in medicine. 2013. DOI: 10.1155/2013/472564.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.