Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics.

Sheng Qiwen, Wang Xiaoli, Syed Musaddeque, Chowdhury Hasanur R, Lee Seungsup, Dvorak Andrew, Shafer Morgan W, Han Ming

СтатьяПеревод пока не подготовлен

Аннотация

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry-Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 1018 n/cm2. The FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

Для цитирования: Sheng Qiwen, Wang Xiaoli, Syed Musaddeque, Chowdhury Hasanur R, Lee Seungsup, Dvorak Andrew, Shafer Morgan W, Han Ming. Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics.. The Review of scientific instruments. 2025. DOI: 10.1063/5.0273302.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.