MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apjo.2026.100377

Медицинская библиотека · Asia-Pacific journal of ophthalmology (Philadelphia, Pa.) · 2026

The incremental diagnostic value and clinical utility of tear MMP-9 for dry eye disease: A multicentre analysis and development of a simplified screening model.

Li Wubi, Kang Lin, Shen Yang, Zhou Lyubang, Xiao Feiyue, Wu Yuhan, Deng Yayuan, Chen Di, Li Ying, Zhang Shihong, Xie Hongbin, Wang Min, Li Shaowei, Zhao Chan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the incremental diagnostic value of tear matrix metalloproteinase-9 (MMP-9) in dry eye disease (DED) and validate a simplified diagnostic model suitable for primary care.

METHODS

This multicentre study analysed 580 participants (294 DED, 286 controls) from three Centres. Diagnostic performance was evaluated using Generalised Linear Mixed-Effects Models (GLMMs) to adjust for Centre heterogeneity. Three models were compared: (1) Traditional (Ocular Surface Disease Index [OSDI], non-invasive tear breakup time [NIBUT], Schirmer I test, and corneal fluorescein staining [CFS]), (2) Trad + MMP-9, and (3) Simplified (OSDI, Schirmer I test, and MMP-9). Performance was assessed via area under the receiver operating characteristic curve (AUC), Net Reclassification Improvement (NRI), Decision Curve Analysis (DCA), and Leave-One-Centre-Out Cross-Validation (LOCO-CV).

RESULTS

The Trad + MMP-9 model achieved the highest discrimination (AUC 0.982) and calibration. Adding MMP-9 yielded significant risk reclassification improvement (Continuous NRI 0.495, p<0.001) over the Traditional model. A Simplified model (OSDI, Schirmer I test, MMP-9) achieved an AUC of 0.969, statistically comparable to the Traditional model, and demonstrated robust external validity in LOCO-CV. Tear MMP-9 levels correlated strongly with symptom burden (OSDI) independent of clinical signs.

CONCLUSION

Tear MMP-9 provides significant incremental diagnostic value, enabling a simplified, high-accuracy diagnostic strategy that omits slit-lamp examination, potentially expanding DED screening capabilities.

Для цитирования: Li Wubi, Kang Lin, Shen Yang, Zhou Lyubang, Xiao Feiyue, Wu Yuhan, Deng Yayuan, Chen Di, Li Ying, Zhang Shihong, Xie Hongbin, Wang Min, Li Shaowei, Zhao Chan. The incremental diagnostic value and clinical utility of tear MMP-9 for dry eye disease: A multicentre analysis and development of a simplified screening model.. Asia-Pacific journal of ophthalmology (Philadelphia, Pa.). 2026. DOI: 10.1016/j.apjo.2026.100377.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.