Perioperative aortic dissection rupture after endovascular stent graft placement for treatment of type B dissection.

Huang Wen-hui, Luo Song-yuan, Luo Jian-fang, Liu Yuan, Fan Rui-xin, Xue Ling, Yang Fang, Kang Hui-yuan, Gu Meng-nan, Liu Zhen, Xie Nian-jin, Dong Hao-jian, Ni Zhong-han, Huang Mei-ping, Chen Ji-yan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The perioperative aortic dissection (AD) rupture is a severe event after endovascular stent graft placement for treatment of type B AD. However, this life-threatening complication has not undergone systematic investigation. The aim of the study is to discuss the reasons of AD rupture after the procedure.

METHODS

The medical record data of 563 Stanford type B AD patients who received thoracic endovascular repair from 2004 to December 2011 at our institution were collected and analyzed. Double entry and consistency checking were performed with Epidata software.

RESULTS

Twelve patients died during the perioperation after thoracic endovascular repair, with an incidence of 2.1%, 66.6% were caused by aortic rupture and half of the aortic rupture deaths were caused by retrograde type A AD. In our study, 74% of the non-rupture surviving patients had the free-flow bare spring proximal stent implanted, compared with 100% of the aortic rupture patients (74% vs. 100%, P = 0.213). The aortic rupture patients are more likely to have ascending aortic diameters = 4 cm (62.5% vs. 9.0%, P = 0.032), involvement the aortic arch concavity (62% vs. 27%, P = 0.041) and have had multiple stents placed (P = 0.039).

CONCLUSIONS

Thoracic AD endovascular repair is a safe and effective treatment option for AD with relative low in-hospital mortality. AD rupture may be more common in arch stent-graft patients with an ascending aortic diameter = 4 cm and with severe dissection that needs multi-stent placement. Attention should be paid to a proximal bare spring stent that has a higher probability of inducing an AD rupture. Post balloon dilation should be performed with serious caution, particularly for the migration during dilation.

Для цитирования: Huang Wen-hui, Luo Song-yuan, Luo Jian-fang, Liu Yuan, Fan Rui-xin, Xue Ling, Yang Fang, Kang Hui-yuan, Gu Meng-nan, Liu Zhen, Xie Nian-jin, Dong Hao-jian, Ni Zhong-han, Huang Mei-ping, Chen Ji-yan. Perioperative aortic dissection rupture after endovascular stent graft placement for treatment of type B dissection.. Chinese medical journal. 2013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.