MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2024.08.016

Медицинская библиотека · Academic radiology · 2024

Accuracy of 18F-FDG PET Imaging in Differentiating Parkinson's Disease from Atypical Parkinsonian Syndromes: A Systematic Review and Meta-Analysis.

Zhao Tailiang, Wang Bingbing, Liang Wei, Cheng Sen, Wang Bin, Cui Ming, Shou Jixin

СтатьяМетаанализСистематический обзорПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVE

To quantitatively assess the accuracy of 18F-FDG PET in differentiating Parkinson's Disease (PD) from Atypical Parkinsonian Syndromes (APSs).

METHODS

PubMed, Embase, and Web of Science databases were searched to identify studies published from the inception of the databases up to June 2024 that used 18F-FDG PET imaging for the differential diagnosis of PD and APSs. The risk of bias in the included studies was assessed using the QUADAS-2 or QUADAS-AI tool. Bivariate random-effects models were used to calculate the pooled sensitivity, specificity, and the area under the curves (AUC) of summary receiver operating characteristic (SROC).

RESULTS

24 studies met the inclusion criteria, involving a total of 1508 PD patients and 1370 APSs patients. 12 studies relied on visual interpretation by radiologists, of which the pooled sensitivity, specificity, and SROC-AUC for direct visual interpretation in diagnosing PD were 96% (95%CI: 91%, 98%), 90% (95%CI: 83%, 95%), and 0.98 (95%CI: 0.96, 0.99), respectively; the pooled sensitivity, specificity, and SROC-AUC for visual interpretation supported by univariate algorithms in diagnosing PD were 93% (95%CI: 90%, 95%), 90% (95%CI: 85%, 94%), and 0.96 (95%CI: 0.94, 0.97), respectively. 12 studies relied on artificial intelligence (AI) to analyze 18F-FDG PET imaging data. The pooled sensitivity, specificity, and SROC-AUC of machine learning (ML) for diagnosing PD were 87% (95%CI: 82%, 91%), 91% (95%CI: 86%, 94%), and 0.95 (95%CI: 0.93, 0.96), respectively. The pooled sensitivity, specificity, and SROC-AUC of deep learning (DL) for diagnosing PD were 97% (95%CI: 95%, 98%), 95% (95%CI: 89%, 98%), and 0.98 (95%CI: 0.96, 0.99), respectively.

CONCLUSION

18F-FDG PET has a high accuracy in differentiating PD from APS, among which AI-assisted automatic classification performs well, with a diagnostic accuracy comparable to that of radiologists, and is expected to become an important auxiliary means of clinical diagnosis in the future.

Для цитирования: Zhao Tailiang, Wang Bingbing, Liang Wei, Cheng Sen, Wang Bin, Cui Ming, Shou Jixin. Accuracy of 18F-FDG PET Imaging in Differentiating Parkinson's Disease from Atypical Parkinsonian Syndromes: A Systematic Review and Meta-Analysis.. Academic radiology. 2024. DOI: 10.1016/j.acra.2024.08.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.