MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ene.16423

Медицинская библиотека · European journal of neurology · 2024

Remote levodopa challenge test in Parkinson's disease: Feasibility, reliability, validity and economic value.

Zeng Zhitong, Lin Zhengyu, Chen Zhonglue, Wan Xiaonan, Zhou Haiyan, Zhang Chencheng, Sun Bomin, Ren Kang, Li Dianyou

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: The aim was to demonstrate the feasibility, reliability and validity of an in-home remote levodopa challenge test (LCT), as delivered through an online platform, for patients with Parkinson's disease (PwPD).

METHODS

Patients with Parkinson's disease eligible for deep brain stimulation surgery screening were enrolled. Participants sequentially received an in-home remote LCT and an in-hospital standard LCT (separated by 2.71 weeks). A modified Movement Disorder Society Unified Parkinson's Disease Rating Scale Part III omitting rigidity and postural stability items was used in the remote LCT. The reliability of the remote LCT was evaluated using the intraclass correlation coefficient and the concurrent validity was evaluated using the Pearson's correlation coefficient r between the levodopa responsiveness of the remote and standard LCT.

RESULTS

Out of 106 PwPD screened, 80 (75.5%) completed both the remote and standard LCT. There was a good reliability (intraclass correlation coefficient 0.81, 95% confidence interval 0.69-0.88) and a strong correlation (r = 0.84, 95% confidence interval 0.77-0.90) between the levodopa responsiveness of the remote and standard LCT. The mean cost for PwPD was estimated to be reduced by 91% by using the remote LCT.

CONCLUSION

The remote LCT is feasible, reliable and valid and may reduce healthcare-related costs for PwPD and their caregivers.

Для цитирования: Zeng Zhitong, Lin Zhengyu, Chen Zhonglue, Wan Xiaonan, Zhou Haiyan, Zhang Chencheng, Sun Bomin, Ren Kang, Li Dianyou. Remote levodopa challenge test in Parkinson's disease: Feasibility, reliability, validity and economic value.. European journal of neurology. 2024. DOI: 10.1111/ene.16423.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.