MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pcbi.1014555

Медицинская библиотека · PLoS computational biology · 2026

Body surface potential driven personalisation of electrophysiological digital twins in hypertrophic cardiomyopathy.

Malik Shambhavi, Cicci Ludovica, Qayyum Abdul, Ghelani Rahul, Chow Ji-Jian, Mohal Jagdeep Singh, Whinnett Zachary I, Varnava Amanda, Plank Gernot, Kanagaratnam Prapa, Niederer Steven A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Hypertrophic cardiomyopathy (HCM) is associated with marked inter-patient heterogeneity in ventricular electrophysiology, contributing to arrhythmic risk that is insufficiently captured by current clinical methods. Electrocardiographic imaging (ECGI) provides high-density body surface potential (BSP) measurements but remains largely descriptive. Computational modelling offers a mechanistic framework to interpret BSP signals in terms of underlying tissue-level properties.

METHODS AND FINDINGS: We developed a BSP-driven workflow to construct patient-specific electrophysiology (EP) models of HCM by integrating multimodal clinical imaging with Bayesian model calibration. Anatomically detailed torso-heart finite-element models were generated for 17 HCM patients using thoracic computed tomography (CT), cardiac magnetic resonance imaging (CMR), and 252-electrode BSP recordings. Ventricular depolarisation and repolarisation were simulated using a reaction-eikonal (RE) formulation coupled to a biophysically detailed ToR-ORd-dynCl ionic model. Emulator-based Bayesian history matching (HM) was used to personalise EP parameters, with staged calibration of QRS and T-wave morphology informed by targeted sensitivity analysis. The calibrated cohort reproduced clinical BSP morphology with Pearson correlation coefficient (PCC) [Formula: see text] for a median of 94.0% (IQR: 91.6 to 96.8%) of electrodes, achieving a median PCC of 0.89 (IQR: 0.80 to 0.94) across the full 252-electrode vest. Calibration substantially reduced uncertainty in the high-dimensional EP parameter space while yielding physiologically plausible conduction and repolarisation properties. Models calibrated exclusively to sinus rhythm robustly generalised to right-ventricular (RV) apical pacing without parameter retuning, reproducing clinically observed pacing-induced trends in depolarisation and repolarisation. Exploratory analysis revealed biologically consistent associations between inferred EP parameters and patient demographics.

CONCLUSIONS

This study demonstrates that high-density BSP data can be used to functionally personalise mechanistic EP in HCM. The framework captures intrinsic patient-specific EP properties and generalises beyond the calibration condition, supporting its use for mechanistic investigation of arrhythmogenic substrate.

Для цитирования: Malik Shambhavi, Cicci Ludovica, Qayyum Abdul, Ghelani Rahul, Chow Ji-Jian, Mohal Jagdeep Singh, Whinnett Zachary I, Varnava Amanda, Plank Gernot, Kanagaratnam Prapa, Niederer Steven A. Body surface potential driven personalisation of electrophysiological digital twins in hypertrophic cardiomyopathy.. PLoS computational biology. 2026. DOI: 10.1371/journal.pcbi.1014555.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.