Biodegradable or durable polymer drug-eluting stents in patients with coronary artery disease: ten-year outcomes of the randomised NEXT Trial.

Natsuaki Masahiro, Watanabe Hirotoshi, Morimoto Takeshi, Kozuma Ken, Kadota Kazushige, Muramatsu Toshiya, Nakagawa Yoshihisa, Akasaka Takashi, Hanaoka Keiichi Igarashi, Tanabe Kengo, Morino Yoshihiro, Ishikawa Tetsuya, Katoh Harumi, Nishikawa Hideo, Tamura Toshihiro, Ono Koh, Yamamoto Ko, Ishihara Takayuki, Abe Mitsuru, Taniguchi Ryoji, Ikari Yuji, Okada Kozo, Kimura Takeshi

СтатьяРандомизированное исследованиеEquivalence TrialПеревод пока не подготовлен

Аннотация

BACKGROUND

There are no randomised trials reporting clinical outcomes of biodegradable polymer biolimus-eluting stents (BP-BES) and durable polymer everolimus-eluting stents (DP-EES) at 10 years.

AIMS: We aimed to compare the 10-year clinical outcomes between BP-BES and DP-EES.

METHODS

The randomised NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-eluting Stent Trial (NEXT) was originally designed to evaluate the non-inferiority of BP-BES relative to DP-EES with the primary efficacy endpoint of target lesion revascularisation (TLR) at 1 year and the primary safety endpoint of death or myocardial infarction (MI) at 3 years. In this extended follow-up study, clinical outcomes were compared from 1 year after stent implantation up to 10 years between patients with BP-BES and DP-EES.

RESULTS

From May to October 2011, NEXT enrolled a total of 3,241 patients from 98 centres in Japan. The current study population consisted of 2,417 patients (1,204 patients with BP-BES and 1,213 with DP-EES) from 66 centres that agreed to participate in the extended study. Complete 10-year follow-up was achieved in 87.5% of patients. The cumulative 10-year incidence of death or MI was 34.0% in the BP-BES group and 33.1% in the DP-EES group (hazard ratio [HR] 1.04, 95% confidence interval [CI]: 0.90-1.20; p=0.58). TLR occurred in 15.9% of patients in the BP-BES group and in 14.1% of the DP-EES group (HR 1.12, 95% CI: 0.90-1.40; p=0.32). In a landmark analysis at 1 year, the cumulative incidences of death or MI and TLR were not significantly different between the 2 groups.

CONCLUSIONS

The safety and efficacy outcomes for BP-BES were not significantly different from those for DP-EES at 1 year and up to 10 years after stent implantation.

Для цитирования: Natsuaki Masahiro, Watanabe Hirotoshi, Morimoto Takeshi, Kozuma Ken, Kadota Kazushige, Muramatsu Toshiya, Nakagawa Yoshihisa, Akasaka Takashi, Hanaoka Keiichi Igarashi, Tanabe Kengo, Morino Yoshihiro, Ishikawa Tetsuya, Katoh Harumi, Nishikawa Hideo, Tamura Toshihiro, Ono Koh, Yamamoto Ko, Ishihara Takayuki, Abe Mitsuru, Taniguchi Ryoji, Ikari Yuji, Okada Kozo, Kimura Takeshi. Biodegradable or durable polymer drug-eluting stents in patients with coronary artery disease: ten-year outcomes of the randomised NEXT Trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2023. DOI: 10.4244/eij-d-23-00076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.