MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12928-023-00938-7

Медицинская библиотека · Cardiovascular intervention and therapeutics · 2023

Very short-term tissue coverage of the CD34 antibody-covered sirolimus-eluting stent: an optical coherence tomography study.

Matsumoto Tadahiro, Kitahara Hideki, Yamazaki Tatsuro, Hiraga Takashi, Yamashita Daichi, Sato Takanori, Saito Yuichi, Kato Ken, Kobayashi Yoshio

СтатьяПеревод пока не подготовлен

Аннотация

It is well known that patients with acute myocardial infarction (AMI) have delayed vessel healing despite accelerated endothelial progenitor cells (EPC) mobilization. The COMBO stent is a unique biodegradable-polymer sirolimus-eluting stent with an anti-CD34 antibody coating which captures EPC and potentially promotes vessel healing. However, there are limited data about strut tissue coverage at the very short-term period after COMBO stent implantation. This was a prospective study to investigate strut tissue coverage within 1 month after COMBO stent implantation using optical coherence tomography (OCT). Struts fully covered with tissue were defined as covered, and struts with distance from lumen surface longer than strut plus polymer thickness were defined as malapposed. Mean tissue thickness was measured only in apposed struts. A total of 8173 struts of 33 lesions in 32 patients were analyzed at an average of 19.8 ± 4.6 days after COMBO stent implantation. In lesion-level analysis, the rate of covered struts was 89.6 ± 7.2%, the rate of malapposed struts was 0.9 ± 2.0% and mean tissue thickness was 46.8 ± 14.3 µm. In comparison between AMI (n = 12) and non-AMI (n = 21) patients, there were no significant differences in the rate of covered struts (88.4 ± 8.4% vs. 90.2 ± 6.6%, p = 0.48) and mean tissue thickness (46.8 ± 13.7 µm vs. 46.9 ± 15.0 µm, p = 0.98). Multivariable analysis demonstrated that time from implantation to OCT imaging was significantly associated with mean tissue thickness. The COMBO stent had substantial tissue coverage at the very short-term period after implantation even in AMI patients, and follow-up time had an impact on vessel healing.

Для цитирования: Matsumoto Tadahiro, Kitahara Hideki, Yamazaki Tatsuro, Hiraga Takashi, Yamashita Daichi, Sato Takanori, Saito Yuichi, Kato Ken, Kobayashi Yoshio. Very short-term tissue coverage of the CD34 antibody-covered sirolimus-eluting stent: an optical coherence tomography study.. Cardiovascular intervention and therapeutics. 2023. DOI: 10.1007/s12928-023-00938-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.