MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brachy.2023.04.010

Медицинская библиотека · Brachytherapy · 2023

Dose at posterior-inferior border of symphysis point: A predictor for vaginal stricture in cervical cancer.

Singh Ankita, Mani Nilesh, Aggarwal Lalit M, Agarwal Sumit, Mourya Ankur, Verma Ashish, Bagchi Antara, Gupta Neha, Choudhary Sunil

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study the effect of various dose-volume parameters on the severity of vaginal stricture (VS) and the correlation of the latter with the posterior-inferior border of symphysis (PIBS) points in locally advanced cervical cancer patients treated with concurrent chemoradiation and brachytherapy.

METHODS AND MATERIALS: A prospective study was done on 45 histologically proven locally advanced cervical cancer patients between January 2020 and March 2021. All of them were treated with concurrent chemoradiation with 6 MV photon linear accelerator to a dose of 45 Gy/25 fractions in 5 weeks. Twenty-three patients were treated with intracavitary brachytherapy with a dose of 7 Gy/fraction/week for three fractions. Twenty-two patients were treated with interstitial brachytherapy, with 6 Gy/fraction for four fractions, each fraction 6 h apart. Grading of VS was done as per Common Terminology Criteria for Adverse Events version 5.

RESULTS

The median followup was 21.5 months. About 37.8% of patients had VS with a median duration of 8.0 months (4.0-12 months). About 22.2% had Grade 1, 6.7% had Grade 2, and 8.9% had Grade 3 toxicity. Doses at PIBS and PIBS-2 points had no correlation with vaginal toxicity, however, the dose at PIBS+2 was significantly associated with VS (p = 0.004). The treated length of the vagina at the time of brachytherapy (p = 0.001), initial tumor volume (p = 0.009), and vaginal involvement after completion of external beam radiotherapy (EBRT) (p = 0.01) were also statistically significant with the development of VS of Grade 2 or more.

CONCLUSIONS

Dose at PIBS + 2, treated length of the vagina with brachytherapy, initial tumor volume, and post-EBRT vaginal involvement are strong predictors for the severity of VS.

Для цитирования: Singh Ankita, Mani Nilesh, Aggarwal Lalit M, Agarwal Sumit, Mourya Ankur, Verma Ashish, Bagchi Antara, Gupta Neha, Choudhary Sunil. Dose at posterior-inferior border of symphysis point: A predictor for vaginal stricture in cervical cancer.. Brachytherapy. 2023. DOI: 10.1016/j.brachy.2023.04.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.