MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.116.004875

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2017

Cardiac Resynchronization Therapy Reduces Ventricular Arrhythmias in Primary but Not Secondary Prophylactic Implantable Cardioverter Defibrillator Patients: Insight From the Resynchronization in Ambulatory Heart Failure Trial.

Sapp John L, Parkash Ratika, Wells George A, Yetisir Elizabeth, Gardner Martin J, Healey Jeffrey S, Thibault Bernard, Sterns Laurence D, Birnie David, Nery Pablo B, Sivakumaran Soori, Essebag Vidal, Dorian Paul, Tang Anthony S L

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The RAFT (Resynchronization in Ambulatory Heart Failure Trial) demonstrated that cardiac resynchronization therapy (CRT) reduced both mortality and heart failure hospitalizations in patients with functional class II or III heart failure and widened QRS. We examined the influence of CRT on ventricular arrhythmias in patients with primary versus secondary prophylaxis defibrillator indications.

METHODS AND

RESULTS

All ventricular arrhythmias among RAFT study participants were downloaded and adjudicated by 2 blinded reviewers with an overreader for disagreements and committee review for remaining discrepancies. Incidence of ventricular arrhythmias among patients randomized to CRT-D versus implantable cardioverter defibrillator (ICD) were compared within the groups of patients treated for primary prophylaxis and for secondary prophylaxis. Of 1798 enrolled patients, 1764 had data available for adjudication and were included. Of these, 1531 patients were implanted for primary prophylaxis, while 233 patients were implanted for secondary prophylaxis; 884 patients were randomized to ICD and 880 to CRT-D. During 5953.6 patient-years of follow-up, there were 11 278 appropriate ICD detections of ventricular arrhythmias. In the primary prophylaxis group, CRT-D significantly reduced incidence ventricular arrhythmias in comparison to ICD (hazard ratio, 0.86; 95% confidence interval, 0.74-0.99; P=0.044). This effect was not seen in the secondary prophylaxis group (hazard ratio, 1.14; 95% confidence interval, 0.82-1.58; P=0.45). CRT-D was not associated with significant differences in overall ventricular arrhythmia burden in either group.

CONCLUSIONS

CRT reduced the rate of onset of new ventricular arrhythmias detected by ICDs in patients without a history of prior ventricular arrhythmias. This effect was not observed among patients who had prior ventricular arrhythmias.

CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00251251.

Для цитирования: Sapp John L, Parkash Ratika, Wells George A, Yetisir Elizabeth, Gardner Martin J, Healey Jeffrey S, Thibault Bernard, Sterns Laurence D, Birnie David, Nery Pablo B, Sivakumaran Soori, Essebag Vidal, Dorian Paul, Tang Anthony S L. Cardiac Resynchronization Therapy Reduces Ventricular Arrhythmias in Primary but Not Secondary Prophylactic Implantable Cardioverter Defibrillator Patients: Insight From the Resynchronization in Ambulatory Heart Failure Trial.. Circulation. Arrhythmia and electrophysiology. 2017. DOI: 10.1161/circep.116.004875.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.