MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1039856219889306

Медицинская библиотека · Australasian psychiatry : bulletin of Royal Australian and New Zealand College of Psychiatrists · 2019

Use of ultrabrief pulse width electroconvulsive therapy to induce therapeutic seizures in an elderly patient with a high seizure threshold: a case report.

Plevin David, Waite Susan

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This case report describes a 73-year-old man suffering from unipolar major depression with melancholic features, in whom treatment with electroconvulsive therapy (ECT) proved difficult due to inadequate seizure generation.

METHODS

A number of augmentation strategies were trialled in an attempt to improve seizure quality. Pre-ECT and Post-ECT measurement of symptoms, quality of life and cognition were undertaken with a variety of validated scales.

RESULTS

The single most efficacious strategy to elicit therapeutic seizures was the use of right unilateral (RUL) electrode placement with an ultrabrief pulse width. The patient subsequently had a resolution of his depressive illness, with a concomitant improvement in cognitive functioning.

CONCLUSION

This case demonstrates that a number of ECT augmentation strategies can be used in routine clinical practice for patients with high seizure thresholds. It highlights that UB pulse width may be considered earlier in the treatment course for patients in whom conventional brief pulse ECT fails to generate effective seizures.

Для цитирования: Plevin David, Waite Susan. Use of ultrabrief pulse width electroconvulsive therapy to induce therapeutic seizures in an elderly patient with a high seizure threshold: a case report.. Australasian psychiatry : bulletin of Royal Australian and New Zealand College of Psychiatrists. 2019. DOI: 10.1177/1039856219889306.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.