MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc.2019.8857389

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2019

Estimation of 8-Electrode Configuration for Recognition of Uterine Contraction with Electrohysterogram.

Hao Dongmei, Qiao Xiangyun, Song Xiaoxiao, Wang Ying, Qiu Qian, Jiang Hongqing, Chen Fei

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

As the representative of electrical activity from uterine muscle, electrohysterogram (EHG) is recorded non-invasively by multiple electrodes positioned on the abdominal surface. The purpose of our paper is to estimate different electrode configurations for recognizing uterine contractions (UCs) with EHG signals. 8-electrode configuration was taken as an example to show our novel method with convolutional neural network (CNN) classification and score. The open accessed Icelandic 16-electrode EHG database was adopted in our study. With 8-electrode configuration, EHG signals corresponding to UCs and non-UCs were segmented and saved as image patches. The CNN was established and trained by thousands of EHG segments. The performance of CNN was evaluated by the area under curve (AUC) and accuracy of recognizing UCs and non-UCs. Seven different 8-electrode configurations were scored and ranked. It was found the 8-electrode configuration with 4 on the uterine fundus, 2 on the body and 2 on the cervix achieved the AUC of 0.766 and the highest score of 2.197. Among the configurations we have tried, it is concluded that the 8 electrodes in 4-2-2 configuration placed along the uterus as an upside-down pear could provide the most important information for recognition of UC based on our experiments.

Для цитирования: Hao Dongmei, Qiao Xiangyun, Song Xiaoxiao, Wang Ying, Qiu Qian, Jiang Hongqing, Chen Fei. Estimation of 8-Electrode Configuration for Recognition of Uterine Contraction with Electrohysterogram.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2019. DOI: 10.1109/embc.2019.8857389.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.