MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2007-964899

Медицинская библиотека · International journal of sports medicine · 2007

Increased cx43 and angiogenesis in exercised mouse hearts.

Bellafiore M, Sivverini G, Palumbo D, Macaluso F, Bianco A, Palma A, Farina F

СтатьяПеревод пока не подготовлен

Аннотация

Several studies focused on the macroscopic architecture of increased cardiac wall induced by exercise training. Our goal was to evaluate myocardiocyte, interstitial and vascular component, and connexin-43 expression in endurance-trained mouse hearts. Sixty-three 10-week-old male Swiss mice were divided into four sedentary groups (C0, C15, C30 and C45) and three groups exercised respectively for 15 (T15-D; running intensity [RI]: 3.18 m/min; running duration [RD]: 75 min/first week and 150 min/second week), 30 (T30-D; RI: 3.96 m/min; RD: 150 min/third week and 225 min/fourth week) and 45 days (T45-D; RI: 3.96 m/min and 4.8 m/min, respectively for the fifth and sixth week; RD: 300 min) on a treadmill. Morphometric analyses were performed to quantify myocardiocyte size and number, and the capillary and interstitial connective tissue (ICT) area. We assessed the expression of ventricle myosin light chain-II, vimentin and connexin-43 by western blot analyses. Our results showed a hypertrophy of the interventricular septum and left ventricle in T30-D and T45-D mice that was not due to variations in myofibrillar content, myocardiocyte size and number, or ICT quantity but to a significant increase in the capillary area. The microvascular remodeling was associated with vimentin increased expression in ICT cells and connexin-43 upregulation. The first phenomenon might be related to an enhanced request of remodeling and growth factors; the second suggests a new role of connexin-43 in cardiac angiogenesis.

Для цитирования: Bellafiore M, Sivverini G, Palumbo D, Macaluso F, Bianco A, Palma A, Farina F. Increased cx43 and angiogenesis in exercised mouse hearts.. International journal of sports medicine. 2007. DOI: 10.1055/s-2007-964899.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.