OBJECTIVES

To assess the diagnostic accuracy of a junctional zone (JZ) thickness of ≥ 12 mm and morphological features of the JZ in MRI in diagnosing adenomyosis in a premenopausal study population.

METHODS

This single-center, prospective observational study consecutively enrolled 93 premenopausal women suffering from a benign gynecological condition, from September 2014 to August 2016. Institutional review board approval and written consent were obtained. All participants underwent MRI and hysterectomy with a histopathological examination. MR images were evaluated in a blinded fashion by two independent readers. The maximum junctional zone thickness (JZmax), presence of JZmax ≥ 12 mm, and any irregular appearance of the JZ (defined as irregular outer or inner borders, focal thickening, presence of high-intensity signal foci, or fingerlike indentations at the inner border) were documented, and the diagnostic performance was evaluated with the AUC, chi-square test, and multiple regression.

RESULTS

Adenomyosis was histopathologically confirmed in 57 (61%) of the women. JZmax was not positively correlated with adenomyosis diagnosis (AUC = 0.57, p = 0.26) and did not differ significantly between those with and without adenomyosis (10.3 vs 10.1 mm, p = 0.88), nor was a cutoff of JZmax ≥ 12 mm (n = 30/57 (53%) vs n = 16/36 (44%), p = 0.29). The presence of an irregular JZ showed the best association with adenomyosis among the evaluated signs (sensitivity 74% (95% CI, 60, 85); specificity 83% (95% CI, 67, 94) (p < 0.001)).

CONCLUSIONS

JZmax was not correlated with adenomyosis in the present premenopausal study population, but direct signs of adenomyosis such as irregularities of the JZ provided a good diagnostic accuracy.

KEY POINTS: • Measuring the junctional zone thickness is of limited value for diagnosing adenomyosis with MRI and should not be used for diagnosing adenomyosis in premenopausal women with moderate disease severity. • An irregular appearance of the junctional zone, the presence of myometrial cysts, and adenomyoma appear to provide the highest specificity for diagnosing adenomyosis. • A consensus for the definition and reading of the junctional zone is needed.

Для цитирования: Tellum Tina, Matic Gordana V, Dormagen Johann B, Nygaard Staale, Viktil Ellen, Qvigstad Erik, Lieng Marit. Diagnosing adenomyosis with MRI: a prospective study revisiting the junctional zone thickness cutoff of 12 mm as a diagnostic marker.. European radiology. 2019. DOI: 10.1007/s00330-019-06308-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.