OBJECTIVES
The purpose of the study was to assess the accuracy of hysterosalpingo-contrast sonography (HyCoSy) for evaluation of the uterine cavity.
METHODS
Hysterosalpingo-contrast sonography was compared with hysteroscopy for assessment of the uterine cavity. This work was a descriptive prospective study to assess the concordance between pathologic intrauterine findings using the Cohen κ coefficient. Ninety infertile patients from Puerta de Hierro University Hospital were included in the study. They underwent HyCoSy between June 2016 and April 2017. Fifteen of them had pathologic findings in the uterine cavity during HyCoSy and therefore underwent hysteroscopy. Clinical and sonographic findings were compared in those 15 patients by to evaluate the agreement between both techniques.
RESULTS
In this study, intrauterine sonographic findings on HyCoSy and hysteroscopic features of the uterine cavity reached 100% concordance, with a κ coefficient of 1.000 and a 100% agreement rate.
CONCLUSIONS
Hysterosalpingo-contrast sonography permits a very accurate evaluation of the uterine cavity, which could be of interest for infertile patients who might be examined for tubal patency.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.