Diagnosis of testicular torsion by measuring attenuation of dual wavelengths in transmission geometry across the testis: an experimental study in a rat model.

Canpolat Murat, Yucel Selcuk, Sircan-Kucuksayan Aslinur, Kol Arif, Kazanci H Ozgur, Denkceken Tuba

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To develop a noninvasive and real-time dual-wavelengths optic system to detect testicular torsion in an animal model. Diagnosis of testicular torsion is challenging in emergency conditions and frequently ends with surgical exploration.

MATERIALS AND

METHODS

In this study, 9 male 8-month-old Wistar albino rats weighing an average of 400 g were used. A transverse incision on the upper scrotum was done and the right testis was torsed with a 720° medial rotation. The other testis of each rat was used as the control or sham group. In the sham group, the testicle was moved out of the body but no torsion was applied before repositioning into the scrotum. Transmission of continuous-wave light through all testes at wavelengths of 660 nm and 940 nm were measured.

RESULTS

The ratio of the average intensities of the transmitted light of both wavelengths--660 nm to 940 nm--was used as a parameter to diagnose testis torsion. The ratios were significantly different (P = .001) between the torsion group and control group.

CONCLUSION

Our noninvasive technique measuring attenuation of dual wavelengths in transmission geometry across the testis has the ability to distinguish between the testis with and without torsion on the basis of a threshold value of the ratio.

Для цитирования: Canpolat Murat, Yucel Selcuk, Sircan-Kucuksayan Aslinur, Kol Arif, Kazanci H Ozgur, Denkceken Tuba. Diagnosis of testicular torsion by measuring attenuation of dual wavelengths in transmission geometry across the testis: an experimental study in a rat model.. Urology. 2012. DOI: 10.1016/j.urology.2011.12.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.