Aberration-guided intraocular lens power calculation in keratoconus: ray-tracing optimization.

Vandevenne Magali M S, Aramberri Jaime, Berendschot Tos T J M, Nuijts Rudy M M A, Pérez-Merino Pablo

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the accuracy of ray-tracing optimization (RTO) for predicting postoperative refractive error in keratoconic cataract eyes.

SETTING

University Eye Clinic, Maastricht, the Netherlands.

DESIGN

Case series. Evaluation of technology.

METHODS

22 keratoconic eyes that underwent cataract surgery were included in the study. Anterior and posterior corneal Zernike coefficients, axial distances, and intraocular lens (IOL) geometry were exported to custom-developed RTO algorithms to build patient-specific eye models. Optical quality was quantified with the Visual Strehl of the Optical Transfer Function (VSOTF) ratio. The defocus and astigmatism maximizing VSOTF were taken as the optimal target refraction and compared with postoperative subjective refraction using power vectors (spherical equivalent [SEQ], J 0 , and J 45 ). Agreement was assessed with Bland-Altman analysis, and prediction accuracy was summarized as the percentage within ±0.5 diopters (D) and ±1.0 D.

RESULTS

Bland-Altman analysis showed good agreement between RTO-predicted and postoperative subjective refractions, particularly for SEQ and J 0 (with-the-rule/against-the-rule astigmatism). The percentage of eyes within ±0.5 D of prediction error was 68.2% for SEQ and J 0 and 59.1% for J 45 ; within ±1.0 D, it was 86.3% (SEQ), 81.8% (J 0 ), and 77.3% (J 45 ). Cataract surgery in keratoconic eyes did not induce significant variations in the corneal Zernike coefficients. RTO accuracy was highest when vertical coma (Z 3-1 ) predominated as the main higher-order aberrations (HOAs).

CONCLUSIONS

Aberration-guided RTO provides accurate postoperative refractive predictions in keratoconic cataract eyes. Accuracy is particularly strong in eyes dominated by vertical coma, supporting inclusion of measured HOAs in IOL power selection.

Для цитирования: Vandevenne Magali M S, Aramberri Jaime, Berendschot Tos T J M, Nuijts Rudy M M A, Pérez-Merino Pablo. Aberration-guided intraocular lens power calculation in keratoconus: ray-tracing optimization.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000002029.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.