Biomechanical Comparison of Tendon Coaptation Methods With a Meshed Suture Construct.

Gillis Joshua Allan, Athens Christian M, Rhee Peter C

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Tendon-to-tendon attachment constructs for tendon reconstructions or transfers need to be secure in order to allow early mobilization after surgery. The purpose of this study was to biomechanically compare 2 common constructs secured with a novel mesh suture versus a nonabsorbable braided suture.

METHODS

We used 100 cadaveric tendons to create 5 different tendon coaptation constructs (a to e) (10 coaptations per group): (a) Pulvertaft weave with a braided suture (PTe); (b) mesh suture (PTm); (c) single-pass, side-to-side (SP-STS) coaptation with 30-mm overlap using a mesh suture (SP-STS-30m); (d) SP-STS 50-mm overlap with a mesh suture (SP-STS-50m); and (e) SP-STS with 30-mm tendon overlap using a braided suture (SP-STS-30e). The tensile strength, bulk, gliding resistance, and failure type were compared.

RESULTS

There was no difference between the various tendon constructs and the suture type in terms of coaptation bulk. All SP-STS constructs with mesh suture had higher peak gliding resistance than any of the PT constructs regardless of suture type. Compared with the PT constructs, the SP-STS constructs with mesh or braided suture had a higher peak load, peak load normalized to repair length, and stiffness. Within each tendon coaptation construct group, Pulvertaft or SP-STS, the suture type did not affect any of the investigated parameters.

CONCLUSIONS

The SP-STS constructs are significantly stronger and stiffer than the PT constructs. The SP-STS with mesh suture exhibited greater gliding resistance than the PT constructs and may result in greater gliding resistance through physiological tissue planes. However, the use of a mesh suture did not affect strength, bulk, gliding resistance, or failure type when compared within a construct group.

CLINICAL RELEVANCE: The use of SP-STS constructs for tendon coaptations produces a stronger and stiffer construct than the PT weave; however, the use of a mesh suture may not provide any benefit over a braided suture.

Для цитирования: Gillis Joshua Allan, Athens Christian M, Rhee Peter C. Biomechanical Comparison of Tendon Coaptation Methods With a Meshed Suture Construct.. The Journal of hand surgery. 2020. DOI: 10.1016/j.jhsa.2020.10.003.