MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/end.2014.0572

Медицинская библиотека · Journal of endourology · 2014

GreenLight laser vs diode laser vaporization of the prostate: 3-year results of a prospective nonrandomized study.

Guo Sanwei, Müller Georg, Bonkat Gernot, Püschel Heike, Gasser Thomas, Bachmann Alexander, Rieken Malte

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Laser vaporization of the prostate is one of the alternatives to transurethral resection of the prostate. Short-term studies report a comparable outcome after laser vaporization with the 532 nm 120-W GreenLight high-performance system (HPS) laser and the 980 nm 200 W high-intensity diode (diode) laser. In this study, we analyzed the intermediate-term results of both techniques.

MATERIALS AND

METHODS

From January 2007 to January 2008, 112 consecutive patients with symptomatic benign prostate enlargement were nonrandomly assigned to treatment with the GreenLight laser or the diode laser. Perioperative parameters, postoperative functional outcome, complications, and the reoperation rate at 3 years were analyzed.

RESULTS

Improvement of voiding symptoms (International Prostate Symptom Score, quality-of-life) and micturition parameters (maximum flow rate, postvoid residual volume) showed no significant difference between the HPS group and the diode group. A significantly higher reoperation rate was observed in the diode group in comparison to the HPS group (37.5% vs 8.9%, p=0.0003) due to obstructive necrotic tissue (16.1% vs 0%, p=0.0018), bladder neck stricture (16.1% vs 1.8%, p=0.008), and persisting or recurrent adenoma (5.4% vs 7.1%, p=0.70), respectively.

CONCLUSIONS

Both lasers lead to comparable improvement of voiding parameters and micturition symptoms. Treatment with the 200 W diode laser led to a significantly higher reoperation rate, which might be attributed to a higher degree of coagulation necrosis. Thus, a careful clinical application of this diode laser type is warranted.

Для цитирования: Guo Sanwei, Müller Georg, Bonkat Gernot, Püschel Heike, Gasser Thomas, Bachmann Alexander, Rieken Malte. GreenLight laser vs diode laser vaporization of the prostate: 3-year results of a prospective nonrandomized study.. Journal of endourology. 2014. DOI: 10.1089/end.2014.0572.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.