MedElevator Войти в исследования
← Поиск публикаций

DOI 10.34133/csbj.0234

Медицинская библиотека · Computational and structural biotechnology journal · 2026

Unbiased Long-Read Whole-Genome Sequencing Enables High-Resolution Mapping of Transgene Concatenation and Off-target Genomic Disruption in a Mouse Model.

Yin Jingyi, Huang Lijie, Zhang Jingke, Lok U-Wai, DeRuiter Ryan M, Zhu Xiang-Yang, Krier James D, Kim Yohan, Zhao Yanzhe, Ji Kaipeng, Lucien Fabrice, Lerman Lilach O, Chen Shigao, Huang Chengwu

СтатьяПеревод пока не подготовлен

Аннотация

Objective

This study aims to develop a contrast-free, high-sensitivity ultrasound method, denoted as Radon transform-based flow measurement (R-Flow), for in vivo mapping of microvascular flow vectors and for establishing R-Flow-derived vector-field metrics to noninvasively quantify microcirculatory patterns in liver cirrhosis. Impact Statement: R-Flow enables robust, contrast-free imaging of microvascular dynamics and demonstrates translational feasibility in the human liver. Its direction-aware indices offer pilot in vivo quantification of flow redistribution and remodeling, providing unique insights into hepatic flow dynamics.

Introduction

Microvascular dysfunction is a hallmark of many diseases, yet noninvasive visualization and quantitative assessment of abnormal microcirculation remain limited.

Methods

R-Flow leverages Radon transform to decode red blood cell dynamics from the spatiotemporal domain of ultrasound flow signals, reconstructing velocity vectors at microvascular scale. From these vector maps, unique direction-aware indices are further derived to characterize flow distribution and heterogeneity.

Results

Validated across simulations, phantoms, and in vivo studies, R-Flow provides robust velocity estimation across a wide range (1 to 60 mm/s). Notably, it enables high-sensitivity microvascular flow vector mapping of human liver, showing strong agreement with references (r > 0.9). In a rat model, these direction-aware indices revealed a shift from healthy multipath perfusion in control livers to directionally biased vascular pattern in cirrhotic livers, demonstrating significant correlation with pathological indicators.

Conclusion

R-Flow enables noninvasive, contrast-free mapping of microvascular blood flow velocity and offers a promising approach for high-resolution assessment of microvascular flow characteristics.

Для цитирования: Yin Jingyi, Huang Lijie, Zhang Jingke, Lok U-Wai, DeRuiter Ryan M, Zhu Xiang-Yang, Krier James D, Kim Yohan, Zhao Yanzhe, Ji Kaipeng, Lucien Fabrice, Lerman Lilach O, Chen Shigao, Huang Chengwu. Unbiased Long-Read Whole-Genome Sequencing Enables High-Resolution Mapping of Transgene Concatenation and Off-target Genomic Disruption in a Mouse Model.. Computational and structural biotechnology journal. 2026. DOI: 10.34133/csbj.0234.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.