Impact of overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: pooled analysis of five trials from the international Global RESOLUTE Program.

Farooq Vasim, Vranckx Pascal, Mauri Laura, Cutlip Donald E, Belardi Jorge, Silber Sigmund, Widimsky Petr, Leon Martin, Windecker Stephan, Meredith Ian, Negoita Manuela, van Leeuwen Frank, Neumann Franz-Joseph, Yeung Alan C, Garcia-Garcia Hector M, Serruys Patrick W

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Overlapping first generation sirolimus- and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes--including death and myocardial infarction (MI)--in clinical studies.

OBJECTIVES

To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES).

DESIGN

Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan-Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial.

SETTING

Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrollment criteria were generally unrestrictive.

PATIENTS: 5130 patients.

MAIN OUTCOME MEASURES: 2-year clinical outcomes and 13-month angiographic outcomes.

RESULTS

644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicated comparable cardiac death (2-year overlap vs non-overlap: 3.0% vs 2.1%, p=0.36), major adverse cardiac events (13.3% vs 10.7%, p=0.19), target-vessel MI (3.9% vs 3.4%, p=0.40), clinically driven target vessel revascularisation (7.7% vs 6.5%, p=0.32), and definite/probable stent thrombosis (1.4% vs 0.9%, p=0.28). 13-month adjusted angiographic outcomes were comparable between overlapping and non-overlapping DES.

CONCLUSIONS

Overlapping newer generation DES are safe and effective, with comparable angiographic and clinical outcomes--including repeat revascularisation--to non-overlapping DES.

Для цитирования: Farooq Vasim, Vranckx Pascal, Mauri Laura, Cutlip Donald E, Belardi Jorge, Silber Sigmund, Widimsky Petr, Leon Martin, Windecker Stephan, Meredith Ian, Negoita Manuela, van Leeuwen Frank, Neumann Franz-Joseph, Yeung Alan C, Garcia-Garcia Hector M, Serruys Patrick W. Impact of overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: pooled analysis of five trials from the international Global RESOLUTE Program.. Heart (British Cardiac Society). 2013. DOI: 10.1136/heartjnl-2012-303368.