MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00380-012-0281-2

Медицинская библиотека · Heart and vessels · 2012

Left circumflex coronary artery is protected against no-reflow phenomenon following percutaneous coronary intervention for coronary artery disease.

Nagai Toshiyuki, Hirano Takuro, Tsunoda Mayumi, Hosaka Haruhiko, Kishino Yoshikazu, Katayama Takaharu, Matsumura Keisuke, Miyagawa Takashi, Kohsaka Shun, Anzai Toshihisa, Fukuda Keiichi, Suzuki Masahiro

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Despite the positive impact of percutaneous coronary intervention (PCI) on reducing mortality, a small percentage of patients experience poor myocardial reperfusion following PCI. However, factors associated with no-reflow remain unclear. We investigated clinical factors associated with no-reflow following PCI for coronary artery disease (CAD). We retrospectively analyzed 1622 consecutive CAD patients who underwent PCI over a 5-year period at our institution. Patients were divided into two groups according to the presence (n = 31) or absence (n = 1591) of no-reflow, defined as Thrombolysis in Myocardial Infarction flow grade <3 after PCI. No significant differences in patient characteristics or PCI strategy were seen between the no-reflow and normal flow groups. The incidence of no-reflow was significantly lower in the left circumflex artery (LCx) than in the left anterior descending artery (LAD) (P = 0.0015), with no differences in characteristics or PCI strategy between these two target vessels. Multivariate analysis revealed that involvement of the LCx was an independent protective factor against no-reflow (odds ratio 0.14, 95 % confidence interval 0.02-0.98, P = 0.044). In conclusion, LCx as the target vessel was protective against no-reflow compared with LAD following PCI for CAD. Our results suggest that embolic protection devices may be unnecessary in CAD patients with involvement of LCx.

Для цитирования: Nagai Toshiyuki, Hirano Takuro, Tsunoda Mayumi, Hosaka Haruhiko, Kishino Yoshikazu, Katayama Takaharu, Matsumura Keisuke, Miyagawa Takashi, Kohsaka Shun, Anzai Toshihisa, Fukuda Keiichi, Suzuki Masahiro. Left circumflex coronary artery is protected against no-reflow phenomenon following percutaneous coronary intervention for coronary artery disease.. Heart and vessels. 2012. DOI: 10.1007/s00380-012-0281-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.