MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of invasive cardiology · 2012

Safety and efficacy of drug-eluting balloons in the treatment of drug-eluting in-stent restenosis: experience of a tertiary care hospital.

Dhakam Sajid, Jafferani Asif, Ahmed Hafeez, Rahman Nasir, Gowani Ambreen

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The advent of drug-eluting balloons (DEBs) is a promising development for coronary revascularization procedures, especially for in-stent restenosis (ISR). This study aims to highlight our experience with DEBs in the treatment of drug-eluting ISR at a tertiary care hospital in Pakistan.

METHODS

All patients presenting to our institution from August 2008 to February 2011 with significant drug-eluting in-stent restenosis (DES-ISR) who were eligible to receive treatment via DEB were included in the analysis. Patient baseline characteristics and angiographic data about the lesion characteristics were obtained. Postprocedural and follow-up endpoints, including cardiac death, myocardial infarction, and repeat revascularization, ie, major adverse cardiovascular events (MACE), were included in the analysis.

RESULTS

A total of 26 patients received treatment with DEB in the study period, with a significant number having major predisposing factors for the development of ischemic heart disease (IHD; 46% diabetics; 92% hypertensives). The culprit lesion was most commonly identified in the left anterior descending (31%), with presence of American College of Cardiology/American Heart Association lesion type C in 68% of patients. The SeQuent Please paclitaxel-eluting balloon (B. Braun) was used for revascularization. Patients were followed for a median of 16 months. Only 5 patients (19%) developed MACE during this period.

CONCLUSION

Our experience demonstrates the effectiveness of DEBs in the treatment of drug-eluting ISR, especially in complex lesions with patients having significant risk factors for development of IHD. However, further studies are needed to define their indications in this role.

Для цитирования: Dhakam Sajid, Jafferani Asif, Ahmed Hafeez, Rahman Nasir, Gowani Ambreen. Safety and efficacy of drug-eluting balloons in the treatment of drug-eluting in-stent restenosis: experience of a tertiary care hospital.. The Journal of invasive cardiology. 2012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.