Mitral isthmus ablation using steerable sheath and high ablation power: a single center experience.

Wong Kelvin C K, Qureshi Norman, Jones Michael, Rajappan Kim, Bashir Yaver, Betts Timothy R

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Mitral isthmus ablation is challenging. The use of steerable sheath and high ablation power may improve success rate.

METHODS

This single-center, prospective study enrolled 200 patients who underwent ablation for atrial fibrillation (AF), including mitral isthmus ablation. Mitral isthmus ablation was performed using an irrigated ablation catheter via a steerable sheath (endocardium: maximum power: 40/50 W limited to annular end, maximum temperature: 48 °C; coronary sinus [CS]: maximum power: 25/30 W, maximum temperature: 48 °C). Endpoint was bidirectional mitral isthmus block.

RESULTS

Mitral isthmus block was acutely achieved in 182/200 patients (91%). Sixty-nine percent of patients required CS ablation. Mean total ablation time was 13 ± 6 minutes. There was 1 case of acute circumflex artery occlusion. Mean left atrium (LA) diameter was significantly bigger in patients with unsuccessful mitral isthmus ablation (49 ± 4 mm vs. 43 ± 6 mm; P = 0.0007). In redo procedures, the incidence of reconduction at the mitral isthmus, roof and cavotricuspid isthmus was 44%, 37%, and 29%, respectively. Overall incidence of perimitral flutter was 9%. Prior complex fractionated atrial electrogram ablation was a predictor for microreentrant atrial tachycardia (AT) whereas gaps in linear lesions predicted macroreentrant flutters. After a mean follow-up of 20 ± 9 months, 73% of patients remained free from AF or AT.

CONCLUSION

We reported on a series of mitral isthmus ablation using steerable sheath and high ablation power (50 W). Larger LA diameter was a predictor of failure to achieve mitral isthmus block. The mitral isthmus had a moderately high incidence of re-conduction but was only associated with a relatively low incidence of perimitral flutter.

Для цитирования: Wong Kelvin C K, Qureshi Norman, Jones Michael, Rajappan Kim, Bashir Yaver, Betts Timothy R. Mitral isthmus ablation using steerable sheath and high ablation power: a single center experience.. Journal of cardiovascular electrophysiology. 2012. DOI: 10.1111/j.1540-8167.2012.02380.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.