MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezs201

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2012

Six-year experience with a hybrid stent graft prosthesis for extensive thoracic aortic disease: an interim balance.

Jakob Heinz, Dohle Daniel-Sebastian, Piotrowski Jarowit, Benedik Jaroslav, Thielmann Matthias, Marggraf Guenter, Erbel Raimund, Tsagakis Konstantinos

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To avoid a two-stage surgical approach for complex thoracic aortic disease with its additive mortality and morbidity, a hybrid stent graft prosthesis was introduced 6 years ago for simultaneous treatment of the ascending, arch and descending aortas, relying proximally on a surgical suture line with an integrated distal stent graft for downstream splinting. We report the mid-term single-centre experience.

METHODS

Between January 2005 and March 2011, 77 patients (mean age 59 years, male 75%) with acute (AAD, n = 39) or chronic aortic dissection (CAD, n = 23) DeBakey type I or an extensive thoracic aortic aneurysm (TAA, n = 15) underwent one-stage repair. Periodic follow-up studies (100%, mean 29 months) included repeat aortic computed tomography imaging. Major adverse events (MAEs) were defined as permanent stroke, spinal cord injury and dialysis.

RESULTS

In-hospital mortality was 10% (8 of 77). The incidence of MAE in AAD, CAD and TAA was 5, 13 and 20%, respectively. At the last follow-up, the complete thrombosis of the thoracic false lumen was 92% for AAD, 91% for CAD and the full exclusion of aneurysms 100% in TAA. Throughout the follow-up, freedom from aortic disease-related death was 93% and 5-year survival 79%. Freedom from distal reoperation was 94% in AAD, 95% in CAD and 100% in TAA and the incidence of distal stent graft extension 10% (8 of 77).

CONCLUSIONS

The durable hybrid one-stage repair of complex thoracic aortic disease is feasible with acceptable mortality. Distal reintervention is infrequent and associated with low risk; thus, the indication for the optimization of the peripheral flow using the endovascular aortic repair techniques is gradually widened.

Для цитирования: Jakob Heinz, Dohle Daniel-Sebastian, Piotrowski Jarowit, Benedik Jaroslav, Thielmann Matthias, Marggraf Guenter, Erbel Raimund, Tsagakis Konstantinos. Six-year experience with a hybrid stent graft prosthesis for extensive thoracic aortic disease: an interim balance.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2012. DOI: 10.1093/ejcts/ezs201.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.