Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation.

Aaronson Keith D, Slaughter Mark S, Miller Leslie W, McGee Edwin C, Cotts William G, Acker Michael A, Jessup Mariell L, Gregoric Igor D, Loyalka Pranav, Frazier O H, Jeevanandam Valluvan, Anderson Allen S, Kormos Robert L, Teuteberg Jeffrey J, Levy Wayne C, Naftel David C, Bittman Richard M, Pagani Francis D, Hathaway David R, Boyce Steven W, HeartWare Ventricular Assist Device (HVAD) Bridge to Transplant ADVANCE Trial Investigators

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Contemporary ventricular assist device therapy results in a high rate of successful heart transplantation but is associated with bleeding, infections, and other complications. Further reductions in pump size, centrifugal design, and intrapericardial positioning may reduce complications and improve outcomes.

METHODS AND

RESULTS

We studied a small, intrapericardially positioned, continuous-flow centrifugal pump in patients requiring an implanted ventricular assist device as a bridge to heart transplantation. The course of investigational pump recipients was compared with that of patients implanted contemporaneously with commercially available devices. The primary outcome, success, was defined as survival on the originally implanted device, transplantation, or explantation for ventricular recovery at 180 days and was evaluated for both noninferiority and superiority. Secondary outcomes included a comparison of survival between groups and functional and quality-of-life outcomes and adverse events in the investigational device group. A total of 140 patients received the investigational pump, and 499 patients received a commercially available pump implanted contemporaneously. Success occurred in 90.7% of investigational pump patients and 90.1% of controls, establishing the noninferiority of the investigational pump (P<0.001; 15% noninferiority margin). At 6 months, median 6-minute walk distance improved by 128.5 m, and both disease-specific and global quality-of-life scores improved significantly.

CONCLUSIONS

A small, intrapericardially positioned, continuous-flow, centrifugal pump was noninferior to contemporaneously implanted, commercially available ventricular assist devices. Functional capacity and quality of life improved markedly, and the adverse event profile was favorable.

CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00751972.

Для цитирования: Aaronson Keith D, Slaughter Mark S, Miller Leslie W, McGee Edwin C, Cotts William G, Acker Michael A, Jessup Mariell L, Gregoric Igor D, Loyalka Pranav, Frazier O H, Jeevanandam Valluvan, Anderson Allen S, Kormos Robert L, Teuteberg Jeffrey J, Levy Wayne C, Naftel David C, Bittman Richard M, Pagani Francis D, Hathaway David R, Boyce Steven W, HeartWare Ventricular Assist Device (HVAD) Bridge to Transplant ADVANCE Trial Investigators. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation.. Circulation. 2012. DOI: 10.1161/circulationaha.111.058412.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.