Avoidance of aortic side-clamping for proximal bypass anastomoses: better short-term outcome?
Аннотация
OBJECTIVES
The benefit of off-pump coronary artery bypass (OPCAB) surgery may be reduced by strokes caused by microemboli produced after aortic side-clamping for proximal bypass anastomoses. The Heartstring device allows constructing proximal bypass anastomoses without side-clamping of the aorta.
METHODS
This retrospective study describes 260 consecutive patients who underwent OPCAB surgery; 442 proximal anastomoses were performed with the Heartstring device in this series. Ten percent of the patients were randomly sampled before discharge to undergo a coronary angiogram for assessment of graft patency.
RESULTS
Intraoperative Doppler measurements confirmed regular bypass function. Early mortality occurred in 4 patients (1.5%), and stroke occurred in 2 patients (0.8%). Device-related bleeding was negligible, and there were no cases of aortic dissection. Perioperative ischemia occurred in 8 patients (3.1%). Predischarge coronary angiography evaluations in 25 of the patients (of 260) showed that all 42 Heartstring-assisted anastomoses (of 442) were patent.
CONCLUSIONS
Clampless performance of proximal bypass anastomoses combined with OPCAB is associated with a very low incidence of stroke complications. Short-term follow-up has shown excellent results regarding bypass patency and other adverse events. Prospective randomized trials are required to confirm the advantage of this technique.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.