MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2014.05.001

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2014

Hybrid approach for transcatheter paravalvular leak closure of mitral prosthesis in high-risk patients through transapical access.

Davidavicius Giedrius, Rucinskas Kestutis, Drasutiene Agne, Samalavicius Robertas, Bilkis Valdas, Zakarkaite Diana, Aidietis Audrius

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To report "hybrid" procedure feasibility and the clinical success of transcatheter paravalvular leak closure through apical access.

METHODS

Seven patients (73.6±6.1 years; 4 men) with severe mitral prosthesis paravalvular leak were selected. All patients were at high risk for open surgery because of severe comorbidities and heart failure (New York Heart Association class III-IV).

RESULTS

The defect size was 25±7.8 mm in the long axis and 9.3±2 mm in the short axis. Two defects were detected in 2 patients. The transapical procedure was performed in a "hybrid" surgery room using minithoracotomy and general anesthesia. Three-dimensional transesophageal echocardiography and fluoroscopy were used for imaging. A total of 19 Amplatzer Vascular Plug III devices (St Jude Medical) were implanted in 7 patients, 2.7/patient and 1 to 3/fistula. The procedure time was 150.7±66.8 minutes. In 6 of 7 patients (85.7%), the paravalvular leak was successfully closed, resulting in no or mild residual regurgitation. One patient had moderate regurgitation despite deployment of 3 Amplatzer Vascular Plug III devices. Two patients required blood transfusion related to procedural blood loss. The patients were discharged at 15.3±6.5 days and followed up at 215.7±138.6 days. All but 1 patient reported symptomatic improvement by ≥1 New York Heart Association class at follow-up. One patient died 216 days postoperatively.

CONCLUSIONS

A "hybrid approach" for transcatheter paravalvular leak closure of mitral prosthesis from the apical route is effective in reducing the regurgitation grade and improving functional capacity in high-risk patients. Complete closure of the defect was maintained at follow-up in most patients.

Для цитирования: Davidavicius Giedrius, Rucinskas Kestutis, Drasutiene Agne, Samalavicius Robertas, Bilkis Valdas, Zakarkaite Diana, Aidietis Audrius. Hybrid approach for transcatheter paravalvular leak closure of mitral prosthesis in high-risk patients through transapical access.. The Journal of thoracic and cardiovascular surgery. 2014. DOI: 10.1016/j.jtcvs.2014.05.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.