Аннотация

OBJECTIVES

To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial.

BACKGROUND

Currently, only limited data allow direct comparison of clinical outcomes among patients with acute coronary syndrome treated with a second-generation drug-eluting stent (DES) eluting zotarolimus vs. a first-generation DES eluting sirolimus.

METHODS

Patients with acute coronary syndrome (n=1052) were randomized to treatment with zotarolimus-eluting (n=506) or sirolimus-eluting (n=546) stents and followed for 18 months. The primary composite endpoint, major adverse cardiac events (MACE), was defined as a composite of cardiac death, myocardial infarction or target vessel revascularization.

RESULTS

Zotarolimus-eluting stent treatment compared to sirolimus-eluting stent treatment was associated with increased rates of MACE (8·7% vs. 5·0%; hazard ratio (HR), 1·78; 95% confidence interval (CI), 1·10-2·88; P=0·02) and TVR (6·8% vs. 3·9%; HR, 1·77; 95% CI, 1·03-3·04; P=0·04), while all-cause death, cardiac death, myocardial infarction and definite stent thrombosis did not differ significantly. In the same trial, stable angina pectoris patients (n=1206) were randomized to zotarolimus-eluting (n=614) and sirolimus-eluting (n=592) stents with similar results.

CONCLUSIONS

With and without acute coronary syndromes, patients treated with the sirolimus-eluting stent had better clinical outcomes than those treated with the zotarolimus-eluting stent.

Для цитирования: Thim Troels, Maeng Michael, Kaltoft Anne, Jensen Lisette O, Tilsted Hans H, Hansen Peter R, Kelbaek Henning, Thayssen Per, Ravkilde Jan, Madsen Morten, Sørensen Henrik T, Thuesen Leif, Lassen Jens F. Zotarolimus-eluting vs. sirolimus-eluting coronary stents in patients with and without acute coronary syndromes: a SORT OUT III substudy.. European journal of clinical investigation. 2012. DOI: 10.1111/j.1365-2362.2012.02692.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.