Reduced cortical brain activity with the use of microprocessor-controlled prosthetic knees during walking.

Möller Saffran, Rusaw David, Hagberg Kerstin, Ramstrand Nerrolyn

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Individuals using a lower-limb prosthesis indicate that they need to concentrate on every step they take. Despite self-reports of increased cognitive demand, there is limited understanding of the link between cognitive processes and walking when using a lower-limb prosthesis.

OBJECTIVE

The objective was to assess cortical brain activity during level walking in individuals using different prosthetic knee components and compare them to healthy controls. It was hypothesized that the least activity would be observed in the healthy control group, followed by individuals using a microprocessor-controlled prosthetic knee and finally individuals using a non-microprocessor-controlled prosthetic knee.

STUDY

DESIGN

Cross-sectional study.

METHODS

An optical brain imaging system was used to measure relative changes in concentration of oxygenated and de-oxygenated haemoglobin in the frontal and motor cortices during level walking. The number of steps and time to walk 10 m was also recorded. The 6-min walk test was assessed as a measure of functional capacity.

RESULTS

Individuals with a transfemoral or knee-disarticulation amputation, using non-microprocessor-controlled prosthetic knee ( n = 14) or microprocessor-controlled prosthetic knee ( n = 15) joints and healthy controls ( n = 16) participated in the study. A significant increase was observed in cortical brain activity of individuals walking with a non-microprocessor-controlled prosthetic knee when compared to healthy controls ( p < 0.05) and individuals walking with an microprocessor-controlled prosthetic knee joint ( p < 0.05).

CONCLUSION

Individuals walking with a non-microprocessor-controlled prosthetic knee demonstrated an increase in cortical brain activity compared to healthy individuals. Use of a microprocessor-controlled prosthetic knee was associated with less cortical brain activity than use of a non-microprocessor-controlled prosthetic knee.

CLINICAL RELEVANCE: Increased understanding of cognitive processes underlying walking when using different types of prosthetic knees can help to optimize selection of prosthetic components and provide an opportunity to enhance functioning with a prosthesis.

Для цитирования: Möller Saffran, Rusaw David, Hagberg Kerstin, Ramstrand Nerrolyn. Reduced cortical brain activity with the use of microprocessor-controlled prosthetic knees during walking.. Prosthetics and orthotics international. 2018. DOI: 10.1177/0309364618805260.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.