MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1536/ihj.20-627

Медицинская библиотека · International heart journal · 2021

Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent.

Ogura Kunihiro, Tsujita Hiroaki, Oishi Yosuke, Matsumoto Hidenari, Matsukawa Naoki, Sakai Rikuo, Arai Taito, Sato Shunya, Tanaka Hideaki, Masaki Ryota, Arai Ken, Nomura Kosuke, Kosaki Ryota, Sakai Koshiro, Sekimoto Teruo, Kondo Seita, Tsukamoto Shigeto, Mori Hiroyoshi, Yamamoto Myong Hwa, Wakabayashi Kohei, Suzuki Hiroshi, Ochiai Masahiko, Shinke Toshiro

Clinical StudyСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

A recent thinner strut drug-eluting stent might facilitate early strut coverage after its placement. We aimed to investigate early vascular healing responses after the placement of an ultrathin-strut bioresorbable-polymer sirolimus-eluting stent (BP-SES) compared to those with a durable-polymer everolimus-eluting stent (DP-EES) using optical coherence tomography (OCT) imaging.This study included 40 patients with chronic coronary syndrome (CCS) who underwent OCT-guided percutaneous coronary intervention (PCI). Twenty patients each received either BP-SES or DP-EES implantation. OCT was performed immediately after stent placement (baseline) and at 1-month follow-up.At one month, the percentage of uncovered struts reduced significantly in both the BP-SES (80.9 ± 10.3% to 2.9 ± 1.7%; P < 0.001) and DP-EES (81.9 ± 13.0% to 5.7 ± 1.8%; P < 0.001) groups, and the percentage was lower in the BP-SES group than in the DP-EES group (P < 0.001). In the BP-SES group, the percentage of malapposed struts also decreased significantly at 1 month (4.9 ± 3.7% to 2.6 ± 3.0%; P = 0.025), which was comparable to that of the DP-EES group (2.5 ± 2.2%; P = 0.860). The optimal cut-off value of the distance between the strut and vessel surface immediately after the placement to predict resolved malapposed struts was ≤ 160 μm for BP-SES and ≤ 190 μm for DP-EES.Compared to DP-EES, ultrathin-strut BP-SES demonstrated favorable vascular responses at one month, with a lower rate of uncovered struts and a comparable rate of malapposed struts.

Для цитирования: Ogura Kunihiro, Tsujita Hiroaki, Oishi Yosuke, Matsumoto Hidenari, Matsukawa Naoki, Sakai Rikuo, Arai Taito, Sato Shunya, Tanaka Hideaki, Masaki Ryota, Arai Ken, Nomura Kosuke, Kosaki Ryota, Sakai Koshiro, Sekimoto Teruo, Kondo Seita, Tsukamoto Shigeto, Mori Hiroyoshi, Yamamoto Myong Hwa, Wakabayashi Kohei, Suzuki Hiroshi, Ochiai Masahiko, Shinke Toshiro. Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent.. International heart journal. 2021. DOI: 10.1536/ihj.20-627.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.