MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.29773

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2021

The radioprotective effect of the Cathpax® AIR cabin during interventional cardiology procedures.

Gutierrez-Barrios Alejandro, Angulo-Pain Esther, Noval-Morillas Inmaculada, Cañadas-Pruaño Dolores, de la Lastra Inara Alarcon, Gheorghe Livia, Zayas-Rueda Ricardo, Calle-Perez German, Vázquez-García Rafael

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The use of ionizing radiation during cardiac catheterization interventions adversely impacts the medical staff. Traditional radiation protection equipment is only partially effective. The Cathpax® radiation protection cabin (RPC) has proven to significantly reduce radiation exposure in electrophysiological and neuroradiology interventions. Our objective was to analyze whether the Cathpax® RPC reduces radiation dose in coronary and cardiac structural interventions in unselected real-world procedures.

METHODS AND

RESULTS

In this nonrandomized all-comers prospective study, 119 consecutive cardiac interventional procedures were alternatively divided into two groups: the RPC group (n = 59) and the non-RPC group (n = 60). No significant changes in the characteristics of patients and procedures, average contrast volume, air kerma (AK), dose area-product (DAP) and fluoroscopy time between both groups were apparent. In the RPC group, the first-operator relative radiation exposure was reduced by 78% at the chest and by 70% at the wrist. This effect was consistent during different types of procedures including complex percutaneous interventions and structural procedures.

CONCLUSIONS

Our study demonstrates, for the first time, that the Cathpax® cabin significantly and efficiently reduces relative operator radiation exposure during different types of interventional procedures, confirming its feasibility in a real-world setting.

Для цитирования: Gutierrez-Barrios Alejandro, Angulo-Pain Esther, Noval-Morillas Inmaculada, Cañadas-Pruaño Dolores, de la Lastra Inara Alarcon, Gheorghe Livia, Zayas-Rueda Ricardo, Calle-Perez German, Vázquez-García Rafael. The radioprotective effect of the Cathpax® AIR cabin during interventional cardiology procedures.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2021. DOI: 10.1002/ccd.29773.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.