12-Month outcomes of transcatheter tricuspid valve repair with the PASCAL system for severe tricuspid regurgitation.

Kitamura Mitsunobu, Fam Neil P, Braun Daniel, Ruf Tobias, Sugiura Atsushi, Narang Akhil, Connelly Kim A, Ho Edwin, Nabauer Michael, Hausleiter Jörg, Weber Marcel, Nickenig Georg, Davidson Charles J, Thiele Holger, von Bardeleben Ralph Stephan, Lurz Philipp

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

We investigated the durability of tricuspid regurgitation (TR) reduction and the clinical outcomes through 12 months after transcatheter tricuspid valve repair (TTVr) with the PASCAL Transcatheter Valve Repair System.

BACKGROUND

TTVr has rapidly developed and demonstrated favorable acute outcomes, but longer follow-up data are needed.

METHODS

Overall, 30 patients (age 77 ± 6 years; 57% female) received PASCAL implantation from September 2017 to May 2019 and completed a clinical follow-up at 12 months.

RESULTS

The TR etiology was functional in 25 patients (83%), degenerative in three (10%), and mixed in two (7%). All patients had TR severe or greater (massive or torrential in 80%) and heart failure symptoms (90% in NYHA III or IV) under optimal medical treatment. Single-leaflet device attachment occurred in two patients. Moderate or less TR was achieved in 23/28 patients (82%) at 30 days, which was sustained at 12 months (86%). Two patients underwent repeat TTVr due to residual torrential TR (day 173) and recurrence of severe TR (day 280), respectively. One-year survival rate was 93%; 6 patients required rehospitalization due to acute heart failure. NYHA functional class I or II was achieved in 90% and 6-minute walk distance improved from 275 ± 122 m at baseline to 347 ± 112 m at 12-month (+72 ± 82 m, p < .01). There was no stroke, endocarditis, or device embolization during the follow-up.

CONCLUSIONS

Twelve-month outcomes from this multicenter compassionate use experience with the PASCAL System demonstrated high procedural success, acceptable safety, and significant clinical improvement.

Для цитирования: Kitamura Mitsunobu, Fam Neil P, Braun Daniel, Ruf Tobias, Sugiura Atsushi, Narang Akhil, Connelly Kim A, Ho Edwin, Nabauer Michael, Hausleiter Jörg, Weber Marcel, Nickenig Georg, Davidson Charles J, Thiele Holger, von Bardeleben Ralph Stephan, Lurz Philipp. 12-Month outcomes of transcatheter tricuspid valve repair with the PASCAL system for severe tricuspid regurgitation.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2021. DOI: 10.1002/ccd.29583.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.