m+Medelevator.RU
← Поиск публикаций
Quantitative imaging in medicine and surgery · 2021

Paravalvular leak prediction after transcatheter aortic valve replacement with self-expandable prosthesis based on quantitative aortic calcification analysis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wiktorowicz Agata, Wit Adrian, Malinowski Krzysztof Piotr, Dziewierz Artur, Rzeszutko Lukasz, Dudek Dariusz, Kleczynski Pawel

Аннотация

BACKGROUND: Paravalvular leak (PVL) is one of the most common complications of transcatheter aortic valve replacement (TAVR) and affects short- and long-term outcomes. The aim of this study was to identify the computed tomography (CT) imaging biomarkers that allow PVL after TAVR to be predicted.

METHODS: Patients were included who had severe aortic valve stenosis, had undergone TAVR with a self-expanding valve, and had undergone a pre-procedural CT scan. Data on baseline characteristics, procedural and long-term outcomes were collected retrospectively. We used MATLAB software with a self-developed algorithm for CT scan analysis and found parameters that quantified aortic valve calcifications (AVC) in detail.

RESULTS: Fifty patients were included. The identified CT-derived parameters included AVC size, volume, thickness and density, as well as calcium radial distribution. The volume of the largest calcium block, calcium perimeter and calcium size (assessed by Feret's diameter) showed a strong association with PVL occurrence after TAVR (P=0.012, P=0.001 and P=0.045, respectively). The prognostic model showed that a 10 mm2 increase in the local AVC amount in each valve section was associated with a 9.8% (95% CI: 2-18%; P=0.019) increase in the risk of PVL occurrence in the corresponding area after TAVR. ROC analysis revealed that the cut-off point of the AVC area was 96.5 mm2 in the polar coordinate system presentation. Kaplan-Meier curves showed worse PVL-free survival in patients with more than 96.5 mm2 of calcium area (P=0.013; log-rank).

CONCLUSIONS: Quantitative AVC assessment for PVL prediction may play an important role in screening before TAVR. In future, the use of quantitative AVC assessment as an imaging biomarker in TAVR candidates and the creation and extension of an online database containing quantitative AVC parameters may help to identify high PVL risk patients.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты