m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2021

Meta-Analysis of Valve-in-Valve Transcatheter Aortic Valve Implantation Versus Redo-surgical Aortic Valve Replacement in Failed Bioprosthetic Aortic Valve.

СтатьяМетаанализОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Al-Abcha Abdullah, Saleh Yehia, Boumegouas Manel, Prasad Rohan, Herzallah Khader, Baloch Zulfiqar Qutrio, Abdelkarim Ola, Rayamajhi Supratik, Abela George S

Аннотация

This meta-analysis was conducted to compare clinical outcomes of valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-surgical aortic valve replacement (Redo-SAVR) in failed bioprosthetic aortic valves. We conducted a comprehensive review of previous publications of all relevant studies through August 2020. Twelve observational studies were included with a total of 8,430 patients, and a median-weighted follow-up period of 1.74 years. A pooled analysis of the data showed no significant difference in all-cause mortality (OR 1.15; 95% CI 0.93 to 1.43; p = 0.21), cardiovascular mortality, myocardial infarction, permanent pacemaker implantation, and the rate of moderate to severe paravalvular leakage between ViV-TAVI and Redo-SAVR groups. The rate of major bleeding (OR 0.36; 95% CI 0.16 to 0.83, p = 0.02), procedural mortality (OR 0.41; 95% CI 0.18 to 0.96, p = 0.04), 30-day mortality (OR 0.58; 95% CI 0.45 to 0.74, p <0.0001), and the rate of stroke (OR 0.65; 95% CI 0.52 to 0.81, p = 0.0001) were significantly lower in the ViV- TAVI arm when compared with Redo-SAVR arm. The mean transvalvular pressure gradient was significantly higher post-implantation in the ViV-TAVI group when compared with the Redo-SAVR arm (Mean difference 3.92; 95% CI 1.97 to 5.88, p < 0.0001). In conclusion, compared with Redo-SAVR, ViV-TAVI is associated with a similar risk of all-cause mortality, cardiovascular mortality, myocardial infarction, permanent pacemaker implantation, and the rate of moderate to severe paravalvular leakage. However, the rate of major bleeding, stroke, procedural mortality and 30-day mortality were significantly lower in the ViV-TAVI group when compared with Redo-SAVR.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты